The effects of a pressure demand-type self-contained breathing apparatus (SCBA) (total weight, 15.5 kg) on breathing pattern, gas exchange, and heart rate were studied in 13 firemen. The subjects performed sequential progressive exercise tests on a treadmill both without and with an SCBA. The use of an SCBA consistently limited tidal volume. During submaximal exercise oxygen consumption and heart rate increased remarkably more with the SCBA than without it. Four subjects reached their maximal heart rate with the SCBA. Their mean ventilation rate was 68% and oxygen consumption was 83% of the maximal values attained without the SCBA. The shoulder harness of the heavy SCBA prevented free motion of the thorax, affecting the regulation of breathing, and thus seriously disturbed ventilation and gas exchange, particularly at heavier exercise levels.

摘要

对13名消防员进行了研究,以探讨一种压力需求型自给式呼吸器(SCBA)(总重量15.5千克)对呼吸模式、气体交换和心率的影响。受试者在跑步机上先后进行了不佩戴和佩戴SCBA的连续渐进运动测试。使用SCBA始终会限制潮气量。在次最大运动量运动期间,佩戴SCBA时的耗氧量和心率比不佩戴时显著增加更多。4名受试者佩戴SCBA时达到了最大心率。他们的平均通气率为不佩戴SCBA时所达到最大值的68%,耗氧量为83%。沉重的SCBA的肩带妨碍了胸部的自由活动,影响了呼吸调节,从而严重干扰了通气和气体交换,尤其是在运动量较大时。