Suppr超能文献

使用X射线摄影和超声测量犬胫骨扭转的准确性和可靠性。

Accuracy and reliability of tibial torsion measurement using radiography and ultrasound in dogs.

作者信息

Jeong Minseung, Kwack Kyuman, Kim Jongyeol, Yu Yong, Heo Suyoung

机构信息

Department of Veterinary Surgery, College of Veterinary Medicine, Jeonbuk National University, Jeollabuk-do, Republic of Korea.

出版信息

Vet Med (Praha). 2024 Dec 27;69(12):427-436. doi: 10.17221/50/2024-VETMED. eCollection 2024 Dec.

Abstract

Tibial torsion assessment is crucial for understanding deformities and malalignments that can lead to joint pathologies in dogs. Different methods such as radiography, computed tomography (CT), and three-dimensional (3D) volume-rendering techniques have been employed to measure tibial torsion. This study compared the accuracy and reliability of tibial torsion angle (TTa) measurements obtained using radiography and ultrasound tilting techniques against those obtained using the 3D volume-rendering method in small-to-medium-sized non-chondrodystrophic dogs. Seven dogs with 11 hind limbs were included in this study. Descriptive statistics revealed mean TTa values for radiography (1.6° ± 5.14°), ultrasound (2.92° ± 3.98°), CT (4.57° ± 3.44°), and 3D volume-rendering method (5.29° ± 3.30°). Intraclass correlation coefficient (ICC) analysis indicated excellent intra- and interobserver agreement between the radiography and ultrasound methods. Correlation analysis showed positive correlations between all the methods. These findings demonstrate that radiography and the ultrasound tilting technique are reliable alternatives for measuring TTa. Although slightly lower ICC values were observed than those of the 3D volume-rendering technique, the radiography and ultrasound methods still exhibited good to excellent reliability, suggesting that these alternative methods could be effective diagnostic tools for assessing TTa in clinical settings with high accuracy and reliability.

摘要

胫骨扭转评估对于理解可能导致犬类关节病变的畸形和排列不齐至关重要。已经采用了不同的方法,如X射线摄影、计算机断层扫描(CT)和三维(3D)容积再现技术来测量胫骨扭转。本研究比较了在中小型非软骨发育不良犬中,使用X射线摄影和超声倾斜技术获得的胫骨扭转角(TTa)测量值与使用3D容积再现方法获得的测量值的准确性和可靠性。本研究纳入了7只犬的11条后肢。描述性统计显示,X射线摄影(1.6°±5.14°)、超声(2.92°±3.98°)、CT(4.57°±3.44°)和3D容积再现方法(5.29°±3.30°)的平均TTa值。组内相关系数(ICC)分析表明,X射线摄影和超声方法在观察者内和观察者间具有极好的一致性。相关性分析显示所有方法之间均呈正相关。这些发现表明,X射线摄影和超声倾斜技术是测量TTa的可靠替代方法。尽管观察到的ICC值略低于3D容积再现技术,但X射线摄影和超声方法仍表现出良好至极好的可靠性,这表明这些替代方法可能是在临床环境中以高精度和可靠性评估TTa的有效诊断工具。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/8c76/11742285/c2d83b7f4bb6/VETMED-69-12-124050-g001.jpg