Suppr超能文献

成年近视患者眼部生物测量参数的变异性及相关性研究

A study on the variability and correlation of ocular biological measurement parameters in adult myopic patients.

作者信息

Zhou Fangxing, Chen Nan, Qian Hui, Gong Di, Li Kunke

机构信息

Fuzhou Aier Eye Hospital, Fuzhou, Jiangxi, China.

Eye Hospital, Nanjing Medical University, Nanjing, Jiangsu, China.

出版信息

Front Med (Lausanne). 2025 Jan 7;11:1526703. doi: 10.3389/fmed.2024.1526703. eCollection 2024.

Abstract

OBJECTIVE

This study aims to explore the differences in ocular parameters among adult myopic patients with different degrees of myopia and axial lengths, and to investigate the correlations between these ocular parameters.

METHODS

This single-center observational study collected clinical data from myopic patients aged 18-45 years who visited the Eye Hospital of Nanjing Medical University between January and June 2023. The data included laterality, diopter of spherical power (DS), diopter of cylindrical power (DC), spherical equivalent (SE), axial length (AL), central corneal thickness (CCT), flat meridian keratometry (K1), steep meridian keratometry (K2), mean keratometry (Km), anterior chamber depth (ACD), corneal radius of curvature (CRC), and axial length/corneal radius of curvature ratio (AL/CRC). Following predefined inclusion and exclusion criteria, 1,026 eyes were included in the study. Patients were grouped based on SE and AL parameters into different degrees of myopia. Analysis of variance (ANOVA) and Welch ANOVA were used to compare intergroup differences. Spearman correlation coefficients were calculated to analyze the correlations between parameters, and linear regression and ROC curve analyses were performed.

RESULTS

Significant differences ( < 0.05) were found among mild, moderate, and high myopia groups in parameters such as DS, DC, AL, K1, Km, ACD, CRC, and AL/CRC. Significant differences ( < 0.05) were also found in DS, DC, SE, CCT, K1, K2, Km, ACD, CRC, and AL/CRC among different axial length groups. Spearman correlation analysis showed a strong correlation between AL and DS, SE, and between AL/CRC and DS, SE, AL. Linear regression analysis revealed that the coefficient of determination (R) for AL and SE was 0.699, and for AL/CRC and SE, it was 0.861. ROC curve analysis demonstrated high accuracy for both AL and AL/CRC in identifying high myopia, with an AUC of 0.952 for AL/CRC, which was superior to the AUC of 0.905 for AL ( < 0.05).

CONCLUSION

This study found significant differences in ocular parameters among patients with different degrees of myopia and axial lengths. There was a significant negative correlation between AL, AL/CRC, and SE. Compared to AL, AL/CRC had a stronger correlation with SE and higher accuracy in identifying high myopia.

摘要

目的

本研究旨在探讨不同近视程度和眼轴长度的成年近视患者眼部参数的差异,并研究这些眼部参数之间的相关性。

方法

这项单中心观察性研究收集了2023年1月至6月期间就诊于南京医科大学眼科医院的18 - 45岁近视患者的临床数据。数据包括眼别、球镜度数(DS)、柱镜度数(DC)、等效球镜度(SE)、眼轴长度(AL)、中央角膜厚度(CCT)、平角膜曲率(K1)、陡角膜曲率(K2)、平均角膜曲率(Km)、前房深度(ACD)、角膜曲率半径(CRC)以及眼轴长度/角膜曲率半径比(AL/CRC)。按照预先定义的纳入和排除标准,1026只眼被纳入研究。根据SE和AL参数将患者分为不同程度的近视组。采用方差分析(ANOVA)和韦尔奇方差分析来比较组间差异。计算Spearman相关系数以分析参数之间的相关性,并进行线性回归和ROC曲线分析。

结果

轻度、中度和高度近视组在DS、DC、AL、K1、Km、ACD、CRC和AL/CRC等参数上存在显著差异(<0.05)。不同眼轴长度组在DS、DC、SE、CCT、K1、K2、Km、ACD、CRC和AL/CRC方面也存在显著差异(<0.05)。Spearman相关分析显示AL与DS、SE之间以及AL/CRC与DS、SE、AL之间存在强相关性。线性回归分析显示,AL与SE的决定系数(R)为0.699,AL/CRC与SE的决定系数为0.861。ROC曲线分析表明,AL和AL/CRC在识别高度近视方面均具有较高的准确性,AL/CRC的AUC为0.952,优于AL的AUC为0.905(<0.05)。

结论

本研究发现不同近视程度和眼轴长度的患者眼部参数存在显著差异。AL、AL/CRC与SE之间存在显著负相关。与AL相比,AL/CRC与SE的相关性更强,在识别高度近视方面准确性更高。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/2b03/11746085/34662b394ebf/fmed-11-1526703-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验