Li Xinru, Li Xiaofeng, Tan Lintong, Chen Hu, Lai Yuan
Department of Ophthalmology, The First People's Hospital of Yongkang Affiliated to Hangzhou Medical College, Yongkang, Zhejiang, P. R. China.
School of Ophthalmology and Optometry, Wenzhou Medical University, Zhejiang, P. R. China.
PLoS One. 2025 Jan 24;20(1):e0317179. doi: 10.1371/journal.pone.0317179. eCollection 2025.
To evaluate the corneal biomechanical properties of phacoemulsification in the treatment of cataract patients.
Pertinent studies were searched in PubMed, EMBASE, Web of Science and clinicaltrials.gov., as of November 05, 2024. The reference lists of related published reviews were included as well. This meta-analysis was performed with Stata Software and Review Manager, we used mean difference (MD) to evaluate the statistical consequence, using I2 statistic to assess the heterogeneity. Subgroup analysis were performed under the occurrences of high heterogeneity. We used eleven items to describe the characteristics of included studies, publication bias was performed with Egger's test. The quality assessment were evaluated with 3 items by Newcastle-Ottawa Scale (NOS) items.
Thirteen eligible studies were identified for data synthesis and assessment. According to the result of meta-analysis, the central corneal thickness(CCT) (MD = 10.50, 95% CI: [5.01, 15.98]; P<0.05) and intraocular pressure(IOPg)(MD = -0.73, 95% CI: [-1.26, -0.19]; P<0.05) of cataract patients after phacoemulsification was significantly higher than the control groups. The values of corneal hysteresis(CH) (MD = -0.43, 95% CI: [-0.62, -0.23]; P<0.05) and corneal resistance factor(CRF) (MD = -0.49, 95% CI: [-0.64, -0.33]; P<0.05) after phacoemulsification surgery were statistically lower than the control groups. While the values of IOPcc did not show statistically different (MD = -0.13, 95% CI: [-0.67, 0.41]; P = 0.64).
Included data analysis indicated that the values of CCT, CH, CRF and IOPg showed statistical change in cataract patients after phacoemulsification surgeries compared with control groups. There is a correlation between corneal biomechanics and phacoemulsification surgeries.
评估白内障患者行超声乳化白内障吸除术时的角膜生物力学特性。
截至2024年11月5日,检索PubMed、EMBASE、Web of Science和clinicaltrials.gov等相关研究。还纳入了相关已发表综述的参考文献列表。本荟萃分析使用Stata软件和Review Manager进行,采用均数差(MD)评估统计结果,用I²统计量评估异质性。在异质性较高的情况下进行亚组分析。我们用11项指标描述纳入研究的特征,采用Egger检验进行发表偏倚分析。用纽卡斯尔-渥太华量表(NOS)的3项指标进行质量评估。
确定了13项符合条件的研究进行数据合成和评估。根据荟萃分析结果,白内障患者超声乳化白内障吸除术后的中央角膜厚度(CCT)(MD = 10.50,95%CI:[5.01,15.98];P<0.05)和眼内压(IOPg)(MD = -0.73,95%CI:[-1.26,-0.19];P<0.05)显著高于对照组。超声乳化白内障吸除术后角膜滞后量(CH)(MD = -0.43,95%CI:[-0.62,-0.23];P<0.05)和角膜阻力因子(CRF)(MD = -0.49,95%CI:[-0.64,-0.33];P<0.05)的值在统计学上低于对照组。而眼压测量值(IOPcc)未显示出统计学差异(MD = -0.13,95%CI:[-0.67,0.41];P = 0.64)。
纳入的数据分析表明,与对照组相比,白内障患者超声乳化白内障吸除术后CCT、CH、CRF和IOPg的值有统计学变化。角膜生物力学与超声乳化白内障吸除术之间存在相关性。