Gonzalez-Lara María F, Román-Montes Carla M, Díaz-Lomelí Paulette, Hernández-Ceballos Winston, Morales-Camilo Lizeth, Cervantes-Sánchez Axel, Cordero-Rangel Andrea, Tejeda-Olán Jazmín, Bonifaz-Trujillo Alexandro, Ponce-de-León Alfredo, Martínez-Gamboa Areli
Clinical Microbiology Laboratory, Infectious Diseases Department, Instituto Nacional de Ciencias Médicas y Nutrición Salvador Zubirán, Tlalpan, Mexico City, Mexico.
Plan of Studies in Medicine (PECEM-MD/PhD), Faculty of Medicine, UNAM, Mexico City, Mexico.
J Clin Microbiol. 2025 Mar 12;63(3):e0137124. doi: 10.1128/jcm.01371-24. Epub 2025 Jan 31.
Correct, rapid, and reliable filamentous fungi identification is crucial for timely diagnosis and therapy. We compared the performance of the FFLv4.0 MALDI Biotyper and MSI-2 to identify filamentous fungi from clinical isolates. We analyzed 307 clinical isolates of spp. spp. and and compared them to sequencing as the reference standard. The overall identification rates to genus (), section (), and species complex () level were 96% (296/307) for FFLv4.0 and 78.5% (241/307) for MSI-2. By each genus, correct species identification was achieved by FFLv4.0 and MSI-2 as follows: 72.4% (165/228) and 55.3% (126/228) for species, 17.6% (6/34) and 38.2% (13/34) for species, and 88.9% (40/45) and 55.5% (25/45) for the . The rates of non-identification by FFLv4.0 and MSI-2, respectively, were 4% (9/228) and 18% (41/228) for spp., 0% and 17.6% (6/34) for spp. and 4.4% (2/45) and 42.2% (19/45%) for the . Misidentification rates by FFLv4.0 and MSI-2, respectively, were 16.2% (37/228) and 6.1% (14/228) for species, 67.6% (23/34) and 14.7% (5/34) for spp., and 0% and 2.2% (1/45) for the . The FFLv4.0 MALDI Biotyper outperformed MSI-2 in identifying filamentous fungi from liquid culture spectra.
准确、快速且可靠的丝状真菌鉴定对于及时诊断和治疗至关重要。我们比较了FFLv4.0 MALDI Biotyper和MSI-2从临床分离株中鉴定丝状真菌的性能。我们分析了307株 spp. spp.和 的临床分离株,并将它们与作为参考标准的测序结果进行比较。FFLv4.0对属()、组()和种复合体()水平的总体鉴定率为96%(296/307),MSI-2为78.5%(241/307)。按每个属计算,FFLv4.0和MSI-2实现的正确种鉴定如下: 种为72.4%(165/228)和55.3%(126/228), 种为17.6%(6/34)和38.2%(13/34), 为88.9%(40/45)和55.5%(25/45)。FFLv4.0和MSI-2的未鉴定率分别为: spp.为4%(9/228)和18%(41/228), spp.为0%和17.6%(6/34), 为4.4%(2/45)和42.2%(19/45%)。FFLv4.0和MSI-2的错误鉴定率分别为: 种为16.2%(37/228)和6.1%(14/228), spp.为67.6%(23/34)和14.7%(5/34), 为0%和2.2%(1/45)。在从液体培养光谱中鉴定丝状真菌方面,FFLv4.0 MALDI Biotyper的表现优于MSI-2。