Suppr超能文献

颌间乳胶弹力圈的力降解:体外与体内对比研究

Force Degradation of Intermaxillary Latex Elastics: Comparative In Vitro and In Vivo Study.

作者信息

Ptáčková Lucie, Ličková Barbora, Urbanová Wanda, Sluka David, Portašíková Klaudia, Chamlarová Soňa, Voborná Iva, Dubovská Ivana

机构信息

Institute of Dentistry and Oral Sciences, Faculty of Medicine and Dentistry, Palacký University, Palackého, Olomouc, Czech Republic.

Department of Stomatology 3rd Medical Faculty Charles University and University Hospital Královské Vinohrady, Prague, Czech Republic.

出版信息

Clin Exp Dent Res. 2025 Feb;11(1):e70072. doi: 10.1002/cre2.70072.

Abstract

OBJECTIVE

This study aimed to compare the force degradation of intermaxillary elastics (IE) in vitro and in vivo while stretching the IE to a precise diameter.

MATERIALS AND METHODS

IE 3/16″ medium Dentaurum from five different batches of packaging were analyzed. The in vivo study involved 10 volunteers, of which 100 IE were examined. To achieve three times the original diameter of the elastic, the distance between the upper canine and the lower dental arch was measured. Buttons were then placed in the mouth accordingly, and IE and passive aligners were inserted for five sessions of 48 h each. To investigate in vitro, 100 IE were placed in an incubator set at 37°C in a humid environment and stretched three times their diameter. The force of the elastics was measured in both investigations using a force meter at 0, 2, 8, 24, and 48 h.

RESULTS

In all patients except one, the three times diameter distance extended from the upper canine to the lower second premolar. The force degradation in vivo at 2, 8, 24, and 48 h was 20.58%, 26.78%, 34.81%, and 38.56% and in vitro was 16.38%, 22.83%, 28.32%, and 30.78%.

CONCLUSIONS

The amount of stretching of IE varies for each patient when using standard insertion points. The force of IE decreases exponentially, the force degradation in vivo being higher. The clinician must consider the force decrease when advising the patient of the time interval to change the elastics.

摘要

目的

本研究旨在比较颌间弹力牵引(IE)在体外和体内拉伸至精确直径时的力降解情况。

材料与方法

分析了来自五个不同批次包装的3/16英寸中等强度的登泰克IE。体内研究涉及10名志愿者,共检查了100个IE。为使弹力牵引达到其原始直径的三倍,测量了上颌尖牙与下颌牙弓之间的距离。然后相应地在口腔中放置纽扣,并插入IE和被动矫治器,分五期进行,每期48小时。为进行体外研究,将100个IE置于37°C的潮湿环境培养箱中,拉伸至其直径的三倍。在两项研究中,均使用测力计在0、2、8、24和48小时测量弹力牵引的力。

结果

除一名患者外,所有患者从尖牙到下颌第二前磨牙的距离均延伸至原始直径的三倍。体内2、8、24和48小时的力降解分别为20.58%、26.78%、34.81%和38.56%,体外分别为16.38%、22.83%、28.32%和30.78%。

结论

使用标准插入点时,每个患者的IE拉伸量各不相同。IE的力呈指数下降,体内的力降解更高。临床医生在告知患者更换弹力牵引的时间间隔时,必须考虑力的下降情况。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/ee9b/11783226/2dc5ad17a5cf/CRE2-11-e70072-g002.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验