通过矫治器机械疗法进行牙齿伸出移动时附件使用及其放置的体外生物力学研究

In Vitro Biomechanics of Attachment Use and Their Placement for Extrusive Tooth Movement by Aligner Mechanotherapy.

作者信息

Kaur Harsimrat, Subramanian Arya, Mah James, Heo Giseon, Major Paul W, Romanyk Dan L

机构信息

Faculty of Medicine and Dentistry, University of Alberta, Edmonton, Alberta, Canada.

Mechanical Engineering Department, Faculty of Engineering, University of Alberta, Edmonton, Alberta, Canada.

出版信息

Orthod Craniofac Res. 2025 Jun;28(3):534-539. doi: 10.1111/ocr.12893. Epub 2025 Feb 6.

Abstract

The objective of the presented study was to evaluate the biomechanics of aligners utilising attachments and the effect of their placement for extrusion. An in vitro Orthodontic SIMulator (OSIM) was used to measure forces and moments produced through aligners incorporating attachments. The maxillary teeth on OSIM were digitally scanned to generate an STL model that was modified by placing a rectangular shaped attachment. Four models were designed with variation in attachment placement: Model NA-no attachment; model BA-buccal attachment; model LA-lingual attachment; model BL-both buccal and lingual attachments. Aligners (n = 30/model) were fabricated using a 0.75 mm thick polyethylene terephthalate material using a Biostar machine following the manufacturer's recommendations. A one-way MANOVA, followed by one-way ANOVA was used to test the effect of models on occlusogingival force (Fz) and mesiodistal moment (Mx) at 0.20 mm of gingival displacement of the left lateral incisor. The BL model exerted maximum Fz (1.22 ± 0.20 N), followed by models BA (1.18 ± 0.25 N) and LA (1.07 ± 0.19 N). The model NA exerted a negligible Fz (0.14 ± 0.08 N) that was statistically different from all other models. The models BA and LA generated Mx that has the tendency to tip the crown of tooth lingually (10.00 ± 3.12 Nmm) and buccally (-1.29 ± 2.26 Nmm), respectively. The models show statistically significant differences between models BL, BA and LA. There was no statistically significant difference between models BL and NA. The experimental evidence suggest that attachments on the lateral incisor could improve the predictability of extrusion forces applied with aligners. The models BL and LA provided favourable biomechanics by generating clinically significant extrusion forces without significant tipping of the lateral incisor tooth.

摘要

本研究的目的是评估使用附件的矫治器的生物力学以及附件放置对牙齿伸长的影响。使用体外正畸模拟器(OSIM)来测量通过带有附件的矫治器产生的力和力矩。对OSIM上的上颌牙齿进行数字扫描,以生成一个通过放置矩形附件进行修改的STL模型。设计了四个模型,附件放置方式有所不同:模型NA-无附件;模型BA-颊侧附件;模型LA-舌侧附件;模型BL-颊侧和舌侧均有附件。按照制造商的建议,使用Biostar机器,采用0.75毫米厚的聚对苯二甲酸乙二酯材料制作矫治器(每个模型n = 30个)。采用单因素多元方差分析,随后进行单因素方差分析,以测试模型对左侧侧切牙牙龈位移0.20毫米时的咬合龈向力(Fz)和近远中力矩(Mx)的影响。模型BL产生的Fz最大(1.22±0.20 N),其次是模型BA(1.18±0.25 N)和模型LA(1.07±0.19 N)。模型NA产生的Fz可忽略不计(0.14±0.08 N),与所有其他模型在统计学上有差异。模型BA和LA产生的Mx分别有使牙冠舌倾(10.00±3.12 Nmm)和颊倾(-1.29±2.26 Nmm)的趋势。模型BL、BA和LA之间在统计学上有显著差异。模型BL和NA之间无统计学显著差异。实验证据表明,侧切牙上的附件可以提高使用矫治器施加伸长力的可预测性。模型BL和LA通过产生具有临床意义的伸长力且侧切牙无明显倾斜,提供了有利的生物力学性能。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/f9fe/12056467/cb25a8248cb7/OCR-28-534-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验