Holden B A, Sweeney D F
Acta Ophthalmol (Copenh). 1985 Feb;63(1):100-3. doi: 10.1111/j.1755-3768.1985.tb05225.x.
A Clark-type oxygen sensor and temperature-sensing thermistor embedded in a ring designed to fit into the human palpebral aperture were used to directly measure the oxygen tension and temperature of the upper palpebral conjunctiva in 16 human subjects. The mean oxygen tension was found to be 61.4 +/- 6.9 mmHg, equivalent to an atmosphere of 8.2% oxygen, slightly higher than previously reported. The mean temperature was 36.2 +/- 0.6 degrees C, in good agreement with previous findings. Significant individual differences in both oxygen tension and temperature were apparent.
将一个Clark型氧传感器和一个嵌入环形装置中的温度感应热敏电阻用于直接测量16名人类受试者上睑结膜的氧分压和温度,该环形装置设计用于适配人眼睑裂。结果发现平均氧分压为61.4±6.9 mmHg,相当于含氧量为8.2%的大气环境,略高于先前报道的数值。平均温度为36.2±0.6℃,与先前的研究结果相符。氧分压和温度在个体间均存在显著差异。