Suppr超能文献

角膜和结膜对空气刺激的敏感性。

Corneal and conjunctival sensitivity to air stimuli.

作者信息

Stapleton F, Tan M E, Papas E B, Ehrmann K, Golebiowski B, Vega J, Holden B A

机构信息

Vision CRC, University of New South Wales, Sydney, New South Wales 2052, Australia.

出版信息

Br J Ophthalmol. 2004 Dec;88(12):1547-51. doi: 10.1136/bjo.2004.044024.

Abstract

AIMS

To determine the repeatability of ocular surface sensitivity to mechanical stimulation using air stimuli and the effect of contact lens (CL) wear on sensitivity.

METHODS

Repeatability: 14 subjects (24-39 years) participated. Mechanical sensitivity to warmed (34 degrees C) and ambient (20 degrees C) air was measured for the central cornea (CC), inferior cornea (IC), and inferior conjunctiva (ICON). Measurements were taken on 12 days; six morning and six afternoon measurements. Differences between sites, time of day, and stimulus temperature were evaluated. CL wear: 10 subjects (22-30 years) participated. Measurements were taken at the same time of day, either following no wear, wear of a CL of oxygen permeability [Dk] of 28 x 10(-9) [cm/s][ml O(2)/ml mm Hg] or wear of a CL of Dk 140 x 10(-9) [cm/s][ml O(2)/ml mm Hg]. Differences between sites and wear conditions were evaluated.

RESULTS

Repeatability: Sensitivity varied between sites (p<0.01), time of day (p<0.05), and stimulus temperatures (p<0.01). There were no significant differences between days. Mean thresholds for eye temperature stimuli were; CC 64.4 (SD 28.6) ml/min; IC 84.6 (40.0) ml/min; ICON 120.6 (40.4) ml/min and for ambient temperature stimuli were CC 53.9 (16.0) ml/min, IC 59.0 (20.0) ml/min; ICON 72.6 (43.7) ml/min. CL wear: Sensitivity varied between sites and wear conditions (p<0.05). Conjunctival sensitivity was increased after wear of highly oxygen permeable CLs but unaffected by wear of low oxygen permeable CLs.

CONCLUSIONS

The prototype gas aesthesiometer is able to repeatably measure ocular surface sensitivity and measurements are consistent with previously reported techniques.

摘要

目的

使用空气刺激来确定眼表对机械刺激的敏感性的可重复性以及隐形眼镜佩戴对敏感性的影响。

方法

可重复性:14名受试者(24 - 39岁)参与。测量中央角膜(CC)、下角膜(IC)和下结膜(ICON)对温热(34摄氏度)和环境温度(20摄氏度)空气的机械敏感性。在12天内进行测量;上午6次测量和下午6次测量。评估不同部位、一天中的时间以及刺激温度之间的差异。隐形眼镜佩戴:10名受试者(22 - 30岁)参与。在一天中的同一时间进行测量,分别是未佩戴隐形眼镜、佩戴氧气透过率[Dk]为28×10⁻⁹[cm/s][ml O₂/ml mmHg]的隐形眼镜或佩戴Dk为140×10⁻⁹[cm/s][ml O₂/ml mmHg]的隐形眼镜之后。评估不同部位和佩戴条件之间的差异。

结果

可重复性:敏感性在不同部位(p<0.01)、一天中的时间(p<0.05)以及刺激温度(p<0.01)之间存在差异。不同日期之间无显著差异。眼部温度刺激的平均阈值为;CC 64.4(标准差28.6)ml/min;IC 84.6(40.0)ml/min;ICON 120.6(40.4)ml/min,环境温度刺激的平均阈值为CC 53.9(16.0)ml/min,IC 59.0(20.0)ml/min;ICON 72.6(43.7)ml/min。隐形眼镜佩戴:敏感性在不同部位和佩戴条件之间存在差异(p<0.05)。佩戴高透氧性隐形眼镜后结膜敏感性增加,但低透氧性隐形眼镜佩戴对其无影响。

结论

原型气体麻醉计能够可重复地测量眼表敏感性,且测量结果与先前报道的技术一致。

相似文献

1
Corneal and conjunctival sensitivity to air stimuli.角膜和结膜对空气刺激的敏感性。
Br J Ophthalmol. 2004 Dec;88(12):1547-51. doi: 10.1136/bjo.2004.044024.

引用本文的文献

1
Evaluation of Corneal Sensitivity: Tools We Have.角膜敏感性评估:我们所拥有的工具
Diagnostics (Basel). 2025 Jul 15;15(14):1785. doi: 10.3390/diagnostics15141785.
9
Ocular Surface Pain: A Narrative Review.眼表疼痛:一篇叙述性综述。
Ophthalmol Ther. 2020 Sep;9(3):1-21. doi: 10.1007/s40123-020-00263-9. Epub 2020 Jun 5.

本文引用的文献

3
Diurnal variation of corneal sensitivity and thickness.角膜敏感性和厚度的昼夜变化。
Cornea. 2003 Apr;22(3):205-9. doi: 10.1097/00003226-200304000-00004.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验