Suppr超能文献

较窄宽度的股四头肌肌腱移植物在 ACL 重建中保持有利的生物力学特性。

Smaller Width Quadriceps Tendon Grafts Maintain Advantageous Biomechanical Properties for ACL Reconstruction.

作者信息

Lee Richard C, Voinier Steven D, McCarthy Conor F, Colantonio Donald F, Gee Shawn M, Tucker Christopher J, Helgeson Melvin D, Lopreiato Nicholas P

机构信息

Department of Orthopedic Surgery, Walter Reed National Military Medical Center, Bethesda, Maryland, USA.

Oak Ridge Institute for Science and Education, Oak Ridge, Tennessee, USA.

出版信息

Orthop J Sports Med. 2025 Feb 18;13(2):23259671251318014. doi: 10.1177/23259671251318014. eCollection 2025 Feb.

Abstract

BACKGROUND

Despite clinical evidence of risks in knee arthrofibrosis and graft impingement with larger grafts, the optimal size for quadriceps tendon (QT) autografts in anterior cruciate ligament reconstruction (ACLR) has not been established.

PURPOSE/HYPOTHESIS: This study aimed to evaluate the mechanical properties of full-thickness 6-mm and 8-mm wide QT grafts compared with 10-mm patellar tendon (PT) and 10-mm QT grafts. The hypothesis was that both the 6- and 8-mm QT grafts would exhibit similar or superior ultimate tensile strength compared with the 10-mm PT graft.

STUDY DESIGN

Controlled laboratory study.

METHODS

A total of 18 matched pairs of cadaveric knees were used in this study. From each pair, a 10-mm wide full-thickness QT was harvested from 1 knee. Based on randomization, a 6-mm wide or 8-mm wide full-thickness QT along with a 10-mm wide PT were harvested from the contralateral knee. Each tendon was clamped, tensioned, and cycled on a servohydraulic testing machine before final loading to failure.

RESULTS

The ultimate failure load was 1286 ± 237.3 N for the 10-mm QT, 1056 ± 226.7 N for the 8-mm QT, 935.1 ± 283.8 N for the 6-mm QT, and 816 ± 192.7 N for the 10-mm PT. Ultimate tensile strength differed significantly between the 10-mm and 8-mm QT ( = .004), 10-mm and 6-mm QT ( < .001), 10-mm QT and 10-mm PT ( < .001), and 8-mm QT and 10-mm PT grafts ( < .001), but not between the 6-mm QT and 10-mm PT grafts ( = .152).

CONCLUSION

The 8-mm QT had higher ultimate tensile strength than the 10-mm PT, and the 6-mm QT was comparable to the 10-mm PT. Full-thickness QT grafts <10 mm in width may maintain sufficient tensile strength for ACLR.

CLINICAL RELEVANCE

Given these biomechanical properties, smaller QT graft sizes may be advantageous in minimizing arthrofibrosis risk while maintaining graft strength.

摘要

背景

尽管有临床证据表明较大移植物存在膝关节纤维性关节病和移植物撞击的风险,但前交叉韧带重建(ACLR)中股四头肌肌腱(QT)自体移植物的最佳尺寸尚未确定。

目的/假设:本研究旨在评估6毫米和8毫米宽的全层QT移植物与10毫米髌腱(PT)和10毫米QT移植物相比的力学性能。假设是6毫米和8毫米的QT移植物与10毫米的PT移植物相比,将表现出相似或更高的极限拉伸强度。

研究设计

对照实验室研究。

方法

本研究共使用了18对匹配的尸体膝关节。从每对膝关节中,从1个膝关节获取1条10毫米宽的全层QT。根据随机分组,从对侧膝关节获取1条6毫米宽或8毫米宽的全层QT以及1条10毫米宽的PT。每条肌腱在伺服液压试验机上进行夹紧、拉伸和循环加载,直至最终破坏。

结果

10毫米QT的极限破坏载荷为1286±237.3牛,8毫米QT为1056±226.7牛,6毫米QT为935.1±283.8牛,10毫米PT为816±192.7牛。10毫米和8毫米QT之间(P = 0.004)、10毫米和6毫米QT之间(P < 0.001)、10毫米QT和10毫米PT之间(P < 0.001)以及8毫米QT和10毫米PT移植物之间(P < 0.001)的极限拉伸强度差异显著,但6毫米QT和10毫米PT移植物之间(P = 0.152)无显著差异。

结论

8毫米QT的极限拉伸强度高于10毫米PT,6毫米QT与10毫米PT相当。宽度小于10毫米的全层QT移植物可为ACLR维持足够的拉伸强度。

临床意义

鉴于这些生物力学特性,较小尺寸的QT移植物在将纤维性关节病风险降至最低同时维持移植物强度方面可能具有优势。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/8e70/11833892/2c019fc21ae7/10.1177_23259671251318014-fig1.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验