This study aimed to compare the precision and trueness of digital impressions of the edentulous arch made with different scanners to conventional physical impressions.
A total of 40 impressions of a completely edentulous maxillary arch model ( = 10) were made using different digital impressions with an extraoral scanner, E3 3Shape desktop scanner, as the reference scan, intraoral scanner (TRIOS IOS, and Medit IOS) and Vinyl Polysiloxane impressions (VPS) impression using a Computer-Aided Design and Computer-Aided Manufacturing (CAD-CAM) custom tray. The VPS impression was scanned with the desktop scanner to produce standard tessellation language (STL) files for comparison with the digital impressions made by the Desktop and intraoral scanners. The STL files were super-imposed to a desktop scan and to each other with the same group using Geomagic Control X Software to assess the trueness and precision, respectively. A t-test was conducted for statistical analysis with a significance level of 0.05.
The overall trueness, Medit had the highest deviation compared to the VPS and TRIOS groups with a value of 0.0013 and <0.0001, respectively. In terms of overall precision, TRIOS had a lower deviation than the VPS group, with a value of 0.0002. The TRIOS and Medit groups had statistically comparable results. The desktop scanner showed the highest precision in digitizing completely edentulous cases, followed by the TRIOS scanner. The Medit scanner's trueness had the highest deviation compared to the VPS and TRIOS groups.
本研究旨在比较使用不同扫描仪制作的无牙颌数字印模与传统物理印模的精度和准确性。
使用口外扫描仪、E3 3Shape桌面扫描仪作为参考扫描、口内扫描仪(TRIOS IOS和Medit IOS)以及使用计算机辅助设计和计算机辅助制造(CAD-CAM)定制托盘的乙烯基聚硅氧烷印模(VPS),对一个完全无牙的上颌弓模型制作了总共40个印模(每组 = 10个)。用桌面扫描仪扫描VPS印模以生成标准镶嵌语言(STL)文件,以便与桌面扫描仪和口内扫描仪制作的数字印模进行比较。使用Geomagic Control X软件将STL文件分别与桌面扫描结果以及同一组内的其他文件进行叠加,以分别评估准确性和精度。进行t检验进行统计分析,显著性水平为0.05。
总体准确性方面,与VPS组和TRIOS组相比,Medit的偏差最大,分别为0.0013和<0.0001。在总体精度方面,TRIOS的偏差低于VPS组,值为0.0002。TRIOS组和Medit组的结果在统计学上具有可比性。桌面扫描仪在数字化完全无牙病例时显示出最高的精度,其次是TRIOS扫描仪。与VPS组和TRIOS组相比,Medit扫描仪的准确性偏差最大。