Suppr超能文献

用于确定工人对苄醇蒸气和雾气的个人暴露水平的采样器设计。

Sampler design for determining the personal exposure level of workers to vapor and mist of benzyl alcohol.

作者信息

Aono Hiromi, Arai Kumiko, Ono-Ogasawara Mariko, Yamamuro Kenji, Shimada Masami, Okada Takayuki, Kawamoto Toshihiro

机构信息

Occupational Health Research and Development Center, Japan Industrial Safety and Health Association, Tokyo, Japan.

Japan National Institute of Occupational Safety and Health, Kawasaki, Japan.

出版信息

Environ Occup Health Pract. 2024 Apr 19;6(1). doi: 10.1539/eohp.2023-0022-OA. eCollection 2024.

Abstract

OBJECTIVES

This study aims to develop and validate a sampler to measure workers' exposure to the vapor and mist of benzyl alcohol.

METHODS

Recovery rate, extraction and desorption rates, breakthrough, and storage stability were tested using Slim-J connected to a glass fiber filter upstream (the connected sampler). The recovery rate of the connected sampler was compared with that of XAD-7. Benzyl alcohol on the filter was extracted, and that in Slim-J resin was desorbed by methanol with an internal standard (-dimethylformamide). Benzyl alcohol was quantified through gas chromatography using a flame ionization detector (GC/FID). Air sampling was conducted by attaching the connected sampler to the chest of a worker during bridge paint film removal.

RESULTS

Calibration curves showed linearity with correlation coefficients >0.999. The lower limit of quantification was 0.54 mg/m of the airborne concentration at 5-mL desorption with 120-L air sampling. The recovery rates of the connected sampler were 101-103%, whereas those of XAD-7 were 72-78%. The average extraction efficiency from the filters was 105.3%, whereas those from Slim-J were 94.5%. No breakthrough was recognized by aeration at 1 L/min for 120 min. Benzyl alcohol in the sampler was stable for up to 7 days. The sampled air by the connected sampler during bridge paint film removal indicated an isolated peak by GC/FID.

CONCLUSIONS

The connected sampler is reliable and suitable for measuring levels of personal exposure to benzyl alcohol in vapor and mist phases.

摘要

目的

本研究旨在开发并验证一种用于测量工人苄醇蒸气和雾气暴露水平的采样器。

方法

使用连接上游玻璃纤维滤膜的Slim-J(连接式采样器)测试回收率、萃取和解吸率、穿透率及储存稳定性。将连接式采样器的回收率与XAD-7的回收率进行比较。滤膜上的苄醇用内标物(-二甲基甲酰胺)甲醇进行萃取,Slim-J树脂中的苄醇用甲醇进行解吸。使用火焰离子化检测器(GC/FID)通过气相色谱法对苄醇进行定量。在去除桥梁漆膜过程中,将连接式采样器连接到工人胸部进行空气采样。

结果

校准曲线呈线性,相关系数>0.999。在120升空气采样、5毫升解吸条件下,定量下限为空气中浓度0.54毫克/立方米。连接式采样器的回收率为101-103%,而XAD-7的回收率为72-78%。滤膜的平均萃取效率为105.3%,Slim-J的平均萃取效率为94.5%。在1升/分钟通气120分钟的情况下未观察到穿透。采样器中的苄醇在长达7天内保持稳定。连接式采样器在去除桥梁漆膜过程中采集的空气经GC/FID检测显示出一个孤立峰。

结论

连接式采样器可靠,适用于测量个人在蒸气和雾气阶段苄醇的暴露水平。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/6be7/11841778/a408cc9b2b9f/eohp-6-2023-0022-OA-g001.jpg

相似文献

8
Determination method for nitromethane in workplace air.工作场所空气中硝基甲烷的测定方法。
J Occup Health. 2010;52(3):194-7. doi: 10.1539/joh.m9014. Epub 2010 Apr 2.

本文引用的文献

1
[Not Available].[无可用内容]。
Sangyo Eiseigaku Zasshi. 2021;63(5):179-211. doi: 10.1539/sangyoeisei.S21001.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验