This study aims to develop and validate a sampler to measure workers' exposure to the vapor and mist of benzyl alcohol.
Recovery rate, extraction and desorption rates, breakthrough, and storage stability were tested using Slim-J connected to a glass fiber filter upstream (the connected sampler). The recovery rate of the connected sampler was compared with that of XAD-7. Benzyl alcohol on the filter was extracted, and that in Slim-J resin was desorbed by methanol with an internal standard (-dimethylformamide). Benzyl alcohol was quantified through gas chromatography using a flame ionization detector (GC/FID). Air sampling was conducted by attaching the connected sampler to the chest of a worker during bridge paint film removal.
Calibration curves showed linearity with correlation coefficients >0.999. The lower limit of quantification was 0.54 mg/m of the airborne concentration at 5-mL desorption with 120-L air sampling. The recovery rates of the connected sampler were 101-103%, whereas those of XAD-7 were 72-78%. The average extraction efficiency from the filters was 105.3%, whereas those from Slim-J were 94.5%. No breakthrough was recognized by aeration at 1 L/min for 120 min. Benzyl alcohol in the sampler was stable for up to 7 days. The sampled air by the connected sampler during bridge paint film removal indicated an isolated peak by GC/FID.
The connected sampler is reliable and suitable for measuring levels of personal exposure to benzyl alcohol in vapor and mist phases.
本研究旨在开发并验证一种用于测量工人苄醇蒸气和雾气暴露水平的采样器。
使用连接上游玻璃纤维滤膜的Slim-J(连接式采样器)测试回收率、萃取和解吸率、穿透率及储存稳定性。将连接式采样器的回收率与XAD-7的回收率进行比较。滤膜上的苄醇用内标物(-二甲基甲酰胺)甲醇进行萃取,Slim-J树脂中的苄醇用甲醇进行解吸。使用火焰离子化检测器(GC/FID)通过气相色谱法对苄醇进行定量。在去除桥梁漆膜过程中,将连接式采样器连接到工人胸部进行空气采样。
校准曲线呈线性,相关系数>0.999。在120升空气采样、5毫升解吸条件下,定量下限为空气中浓度0.54毫克/立方米。连接式采样器的回收率为101-103%,而XAD-7的回收率为72-78%。滤膜的平均萃取效率为105.3%,Slim-J的平均萃取效率为94.5%。在1升/分钟通气120分钟的情况下未观察到穿透。采样器中的苄醇在长达7天内保持稳定。连接式采样器在去除桥梁漆膜过程中采集的空气经GC/FID检测显示出一个孤立峰。
连接式采样器可靠,适用于测量个人在蒸气和雾气阶段苄醇的暴露水平。