用于2型糖尿病无创血糖监测的基于拉曼的设备的校准与性能

Calibration and performance of a Raman-based device for non-invasive glucose monitoring in type 2 diabetes.

作者信息

Pors Anders, Korzeniowska Barbara, Rasmussen Markus T, Lorenzen Christian V, Rasmussen Kaspar G, Inglev Rune, Philipps Amalie, Zschornack Eva, Freckmann Guido, Weber Anders, Hepp Karl D

机构信息

RSP Systems, 5260, Odense, Denmark.

Institute for Diabetes Technology, University of Ulm, 89081, Ulm, Germany.

出版信息

Sci Rep. 2025 Mar 25;15(1):10226. doi: 10.1038/s41598-025-95334-x.

Abstract

Raman spectroscopy has been demonstrated as a viable technique for non-invasive glucose monitoring (NIGM). However, its clinical utility is limited by an extended calibration period lasting several weeks. In this study, we address this limitation by employing a pre-trained calibration model, which is individualized through a brief calibration phase consisting of 10 measurements. The performance of the Raman-based NIGM device was evaluated in a clinical trial involving 50 individuals with type 2 diabetes over a 2-day study period. The protocol included a 4-h calibration phase on the first day, followed by validation phases of 4 h and 8 h on days 1 and 2, respectively. NIGM glucose readings were compared with capillary blood glucose measurements, with glucose fluctuations induced by standardized meal challenges. The numerical and clinical accuracy of the NIGM device was evaluated on 1918 paired points and expressed by mean absolute relative difference of 12.8% (95% CI 12.4, 13.2) and consensus error grid analysis showing 100% of NIGM readings in zones A and B. These results highlight the ability to reliably track blood glucose levels in people with type 2 diabetes. The successful introduction of a practical calibration scheme underlines Raman spectroscopy as a promising technology for NIGM and constitutes an important step towards factory calibration.

摘要

拉曼光谱已被证明是一种用于无创血糖监测(NIGM)的可行技术。然而,其临床应用受到长达数周的延长校准期的限制。在本研究中,我们通过采用预训练校准模型来解决这一限制,该模型通过由10次测量组成的简短校准阶段进行个性化设置。基于拉曼的NIGM设备的性能在一项涉及50名2型糖尿病患者的临床试验中进行了评估,研究期为2天。方案包括第一天4小时的校准阶段,随后分别在第1天和第2天进行4小时和8小时的验证阶段。将NIGM血糖读数与毛细血管血糖测量结果进行比较,同时观察标准化饮食挑战引起的血糖波动。在1918个配对点上评估了NIGM设备的数值和临床准确性,平均绝对相对差异为12.8%(95%CI 12.4, 13.2),一致性误差网格分析显示100%的NIGM读数位于A区和B区。这些结果突出了可靠跟踪2型糖尿病患者血糖水平的能力。成功引入实用的校准方案强调了拉曼光谱作为NIGM的一种有前途的技术,并构成了迈向工厂校准的重要一步。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/e136/11937273/de7a2e14f31e/41598_2025_95334_Fig1_HTML.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验