Abstract

This study aims to evaluate the trueness of Kennedy Class III and IV dental arches digitized by different methods and three-dimensionally (3D) printed using stereolithography technology in an in vitro setup. Reference casts (maxillary Kennedy class III and IV) were produced by computer assisted design and manufacture, and linearly measured at occlusocervical, interarch, and edentulous space dimensions. Intraoral scanner (IOS), extraoral scanner (EOS) and cone beam computed tomography (CBCT) digitized the reference casts. Each digital file was 3D-printed using stereolithography technology, totalizing sixty experimental casts (n=10 per group). The same measurements taken from the reference casts were performed on experimental casts. Two-way ANOVA and Bonferroni post-test were used for trueness (distortion between the experimental and reference casts). Distortion was significantly greater for class IV when compared with class III and increased after the 3D-printing step. Among digitizing methods, IOS and EOS had a similar performance and casts from CBCT showed higher distortion, reaching -1.0 and -1.4 mm in the edentulous spaces of digital and 3D-printed cast, respectively. It was possible to conclude that the trueness of Kennedy class III and IV arches were different according to digitizing processes with higher distortion at the edentulous spaces when the cast was digitized by CBCT and converted to a 3D model, compared to IOS and EOS; and in the Kennedy class IV dental arch condition.

摘要

本研究旨在评估在体外设置中,通过不同方法数字化并使用立体光刻技术进行三维(3D)打印的肯尼迪III类和IV类牙弓的准确性。通过计算机辅助设计和制造制作参考模型(上颌肯尼迪III类和IV类),并在咬合颈向、牙弓间和无牙间隙尺寸方面进行线性测量。口内扫描仪(IOS)、口外扫描仪(EOS)和锥形束计算机断层扫描(CBCT)对参考模型进行数字化处理。每个数字文件使用立体光刻技术进行3D打印,共制作六十个实验模型(每组n = 10)。对实验模型进行与参考模型相同的测量。采用双向方差分析和Bonferroni事后检验评估准确性(实验模型与参考模型之间的变形情况)。与III类相比,IV类的变形明显更大,且在3D打印步骤后有所增加。在数字化方法中,IOS和EOS表现相似,CBCT扫描的模型显示出更高的变形,在数字化模型和3D打印模型的无牙间隙中分别达到-1.0和-1.4毫米。可以得出结论,根据数字化过程的不同,肯尼迪III类和IV类牙弓的准确性存在差异,与IOS和EOS相比,当通过CBCT扫描模型并转换为3D模型时,在无牙间隙处变形更大;在肯尼迪IV类牙弓情况下也是如此。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/ac48/11653756/f8521f33688b/1806-4760-bdj-35-e24-5980-gf1.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验