Suppr超能文献

口服高频振荡诱导正常人黏液纤毛清除功能增强。

Increase in mucociliary clearance in normal man induced by oral high frequency oscillation.

作者信息

George R J, Johnson M A, Pavia D, Agnew J E, Clarke S W, Geddes D M

出版信息

Thorax. 1985 Jun;40(6):433-7. doi: 10.1136/thx.40.6.433.

Abstract

Data on the effect on mucociliary clearance of oral high frequency oscillation is conflicting. By means of a technique to superimpose high frequency oscillation on tidal breathing, changes in mucociliary clearance during high frequency oscillation were studied in seven normal non-smokers by monitoring the clearance of inhaled radiolabelled aerosol from the lungs. After inhalation of 5 microns technetium 99m labelled particles under controlled conditions, whole lung clearance was monitored by scintillation counters half hourly for six hours with a final count at 24 hours, from which tracheobronchial deposition and clearance could be calculated. Control and high frequency oscillation studies were performed on separate days in random order. Oral high frequency oscillation was applied by a bass loudspeaker through a mouthpiece to superimpose sinewave oscillations (RMS input pressure 1.2 cm H2O, mean pressure zero) on normal breaths. On high frequency oscillation days 30 minutes of oscillation alternated with 30 min of rest. Between 3 and 4.5 hours mucociliary clearance with high frequency oscillation exceeded control by about 10% (p less than 0.05). The mean time taken to eliminate 90% of deposited radioaerosol from the tracheobronchial tree fell from 4 hours 50 minutes (range 1 h 52 min-6 h 50 min) during control to 3 hours 43 minutes (range 2 hr 28 min-5 hr 54 min) during the high frequency oscillation run (p less than 0.05). Possibly this comfortable, simple technique would be of therapeutic benefit to patients with chronic sputum retention and merits further investigation.

摘要

关于口服高频振荡对黏液纤毛清除功能影响的数据存在矛盾。通过一种在潮气呼吸上叠加高频振荡的技术,对7名不吸烟的正常人进行研究,通过监测吸入的放射性标记气溶胶从肺部的清除情况,来观察高频振荡期间黏液纤毛清除功能的变化。在受控条件下吸入5微米锝99m标记颗粒后,用闪烁计数器每半小时监测全肺清除情况,持续6小时,并在24小时进行最终计数,由此可计算气管支气管沉积和清除情况。对照研究和高频振荡研究在不同日期以随机顺序进行。通过低音扬声器经咬嘴施加口服高频振荡,以在正常呼吸上叠加正弦波振荡(均方根输入压力1.2厘米水柱,平均压力为零)。在高频振荡日,30分钟的振荡与30分钟的休息交替进行。在3至4.5小时之间,高频振荡时的黏液纤毛清除功能比对照时高出约10%(p<0.05)。从气管支气管树中清除90%沉积放射性气溶胶的平均时间从对照期间的4小时50分钟(范围1小时52分钟至6小时50分钟)降至高频振荡期间的3小时43分钟(范围2小时28分钟至5小时54分钟)(p<0.05)。这种舒适、简单的技术可能对慢性痰液潴留患者具有治疗益处,值得进一步研究。

相似文献

2
Radioaerosol assessment of mucociliary clearance: towards definition of a normal range.
Br J Radiol. 1986 Feb;59(698):147-51. doi: 10.1259/0007-1285-59-698-147.
10
Coordination of mucociliary transport in human trachea and intrapulmonary airways.
J Appl Physiol Respir Environ Exerc Physiol. 1981 Nov;51(5):1057-64. doi: 10.1152/jappl.1981.51.5.1057.

本文引用的文献

1
Effects of conventional and high frequency jet ventilation on lung parenchyma.
Crit Care Med. 1982 Aug;10(8):514-6. doi: 10.1097/00003246-198208000-00006.
2
Chest physiotherapy: a review.胸部物理治疗:综述
Eur J Respir Dis. 1982 May;63(3):188-201.
3
4
Lung mucociliary transport during high-frequency ventilation.高频通气期间的肺黏液纤毛转运
Am Rev Respir Dis. 1982 Sep;126(3):452-6. doi: 10.1164/arrd.1982.126.3.452.
6
Airway mucus; production and composition.
Chest. 1981 Dec;80(6 Suppl):799-804.
8
Deposition and clearance of inhaled particles.吸入颗粒的沉积与清除
Bull Eur Physiopathol Respir. 1980 May-Jun;16(3):335-66.
9
Resistance to two-phase gas-liquid flow in airways.气道中对气液两相流的阻力。
J Appl Physiol. 1970 Oct;29(4):464-71. doi: 10.1152/jappl.1970.29.4.464.
10
The viscosity of bronchial secretion.支气管分泌物的粘度。
Clin Sci. 1970 Jan;38(1):145-56. doi: 10.1042/cs0380145.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验