Suppr超能文献

潮气呼吸时叠加高频胸壁振荡的氮清除。

Nitrogen washout during tidal breathing with superimposed high-frequency chest wall oscillation.

作者信息

Harf A, Zidulka A, Chang H K

出版信息

Am Rev Respir Dis. 1985 Aug;132(2):350-3. doi: 10.1164/arrd.1985.132.2.350.

Abstract

In order to assess the efficacy of high-frequency chest wall oscillation (HFCWO) superimposed on tidal ventilation, multiple-breath nitrogen washout curves were obtained in 7 normal seated subjects. To maintain a regular breathing pattern throughout the study, the subjects breathed synchronously with a Harvard ventilator set at a constant tidal volume and frequency for each subject during a trial period. Washout curves were obtained during 3 different maneuvers performed in random order. Series A was the control condition with no superimposed HFCWO. In Series B and C, HFCWO at 5 Hz was superimposed on the regulated tidal breathing; the magnitude of the oscillatory tidal volume measured at the airway opening was 20 ml for Series B and 40 ml for Series C. The nitrogen washout was clearly faster in Series C than in Series A for each subject. In Series B, there was an interindividual variability, with a washout rate either equal to that in Maneuver A or in Maneuver C, or intermediate between the two. When these washout curves were analyzed in terms of a simple monocompartment model, the time constant of the washout was found to decrease by 16 +/- 11% in Series B, and 25 +/- 7% in Series C compared with that in Series A. In this group of normal subjects, the correction of any inhomogeneity in the distribution of the ventilation is unlikely to explain these results because of the close fit of all washout curves to a monoexponential model. It is postulated that during inspiration HFCWO enhances gas mixing in the lung periphery and that during expiration it improves gas mixing in the airways.(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

为了评估叠加在潮气通气上的高频胸壁振荡(HFCWO)的疗效,在7名正常坐姿受试者中获得了多次呼吸氮洗脱曲线。为了在整个研究过程中保持规律的呼吸模式,在试验期间,受试者与哈佛呼吸机同步呼吸,为每个受试者设置恒定的潮气量和频率。在以随机顺序进行的3种不同操作过程中获得洗脱曲线。A组为无叠加HFCWO的对照条件。在B组和C组中,5Hz的HFCWO叠加在调节的潮气呼吸上;在气道开口处测量的振荡潮气量大小,B组为20ml,C组为40ml。对于每个受试者,C组的氮洗脱明显比A组快。在B组中,存在个体间差异,洗脱率要么等于操作A或操作C中的洗脱率,要么介于两者之间。当根据简单的单室模型分析这些洗脱曲线时,发现与A组相比,B组的洗脱时间常数降低了16±11%,C组降低了25±7%。在这组正常受试者中,由于所有洗脱曲线都非常符合单指数模型,因此不太可能用通气分布中任何不均匀性的校正来解释这些结果。据推测,在吸气期间HFCWO增强了肺周边的气体混合,而在呼气期间它改善了气道中的气体混合。(摘要截短于250字)

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验