This study aimed to evaluate the influence of autoclave sterilization on the cyclic fatigue resistance of nickel-titanium (NiTi) endodontic files with different NiTi alloy treatments.
The research examined Hyflex CM, Bassi Logic, TruNatomy, and ProTaper Gold files, which were divided into control, conventional sterilization, and flash sterilization groups. Poststerilization, the instruments were tested using a custom-made Dynamic Cyclic Fatigue Testing Device replicating root canal procedures. Group 1 used HyFlex CM (size 25, taper 0.04), Group 2 used Bassi Logic (size 25, taper 0.04), Group 3 used TruNatomy (size 25, taper 0.04), and Group 4 used ProTaper Gold (size F1). After rotating each instrument until it fractured, the number of cycles to failure was determined and the time to fracture was noted.
Statistical analysis was conducted using SPSS 26.0 (Statistical software developed by IBM) with one-way ANOVA and Tukey honestly significant difference tests.
HyFlex CM had the highest fracture resistance, whereas ProTaper Gold had the lowest. Sterilization increased the cyclic fatigue resistance of HyFlex CM, Bassi Logic, and ProTaper Gold but decreased that of TruNatomy.
The study concluded that sterilization enhances cyclic fatigue resistance, except for TruNatomy files, and emphasized understanding NiTi alloy properties to mitigate instrument failure.
本研究旨在评估高压蒸汽灭菌对经过不同镍钛(NiTi)合金处理的镍钛根管锉循环疲劳抗力的影响。
该研究检测了Hyflex CM、Bassi Logic、TruNatomy和ProTaper Gold锉,这些锉被分为对照组、传统灭菌组和快速灭菌组。灭菌后,使用定制的动态循环疲劳测试装置模拟根管治疗程序对器械进行测试。第1组使用HyFlex CM(尺寸25,锥度0.04),第2组使用Bassi Logic(尺寸25,锥度0.04),第3组使用TruNatomy(尺寸25,锥度0.04),第4组使用ProTaper Gold(尺寸F1)。旋转每个器械直至其断裂后,确定断裂前的循环次数并记录断裂时间。
使用SPSS 26.0(由IBM开发的统计软件)进行统计分析,采用单因素方差分析和Tukey真实显著性差异检验。
HyFlex CM的抗断裂能力最强,而ProTaper Gold的抗断裂能力最弱。灭菌提高了HyFlex CM、Bassi Logic和ProTaper Gold的循环疲劳抗力,但降低了TruNatomy的循环疲劳抗力。
该研究得出结论,除了TruNatomy锉之外,灭菌可增强循环疲劳抗力,并强调了解NiTi合金性能以减少器械折断。