Assi Fouad, Jabri Brahim, Melalka Lamia, Sekhsokh Yassine, Zouhdi Mimoun
Centre for Doctoral Studies in Life and Health Sciences, Faculty of Medicine and Pharmacy, Mohammed V University in Rabat, Rabat, Morocco.
Central Laboratory of Bacteriology, Serology and Hygiene - Ibn Sina University Hospital Centre of Rabat, Rabat, Morocco.
Iran J Microbiol. 2025 Feb;17(1):92-98. doi: 10.18502/ijm.v17i1.17805.
Urinary tract infections (UTIs) are considered as a major public health issue, often causing complications. Although the traditional cultivation approach is reliable in diagnosis, it is time-consuming, leading to delay in treatment and contributing to antibiotic resistance due to suboptimal empirical treatments. This study aimed to evaluate the performance of a direct, rapid identification technique using MALDI-TOF MS for pathogen identification and antibiotic susceptibility testing in UTIs, aiming to reduce diagnostic time compared to standard culture methods.
In the span of a year, 458 monomicrobial urine samples were analysed using both the standard bacterial culture method and the direct MALDI-TOF MS-based method. Antibiotic susceptibility was directly tested on 20 samples using the disk diffusion method.
The direct identification technique accurately identified 92.14% of microorganisms at the genus level and 60.92% at the species level within an hour, significantly faster than the 24 to 48 hours required by traditional culture methods. The direct antibiotic susceptibility test results were consistent with the standard post-culture method ranging from 60.00% to 100%.
Direct identification using MALDI-TOF MS can improve UTI management by enabling faster pathogen identification and targeted treatments, potentially reducing antibiotic resistance. Further studies are needed in terms of enhancing its clinical utility and reliability.
尿路感染(UTIs)被视为一个重大的公共卫生问题,常引发并发症。尽管传统培养方法在诊断方面可靠,但耗时较长,导致治疗延迟,并因经验性治疗欠佳而促使抗生素耐药性产生。本研究旨在评估一种使用基质辅助激光解吸电离飞行时间质谱(MALDI-TOF MS)的直接、快速鉴定技术在尿路感染中进行病原体鉴定和抗生素敏感性测试的性能,旨在与标准培养方法相比减少诊断时间。
在一年时间里,对458份单一微生物尿液样本同时采用标准细菌培养方法和基于MALDI-TOF MS的直接方法进行分析。使用纸片扩散法对20份样本直接进行抗生素敏感性测试。
直接鉴定技术在一小时内准确鉴定出92.14%的属水平微生物和60.92%的种水平微生物,明显快于传统培养方法所需的24至48小时。直接抗生素敏感性测试结果与标准培养后方法的结果一致,范围在60.00%至100%之间。
使用MALDI-TOF MS进行直接鉴定可通过更快地鉴定病原体和进行靶向治疗来改善尿路感染的管理,可能降低抗生素耐药性。在提高其临床实用性和可靠性方面还需要进一步研究。