Liao Tao, Li Lili, Wei Diefeng, Mao Hejuan, Huang Yanyan, Lu Pengfei, Zhong Dedong, Lu Haiyan, Huang Huiyao, Chen Qi
Visual Science and Optometry Center, The People's Hospital of Guangxi Zhuang Autonomous Region, Guangxi Key Laboratory of Eye Health, Guangxi Health Commission Key Laboratory of Ophthalmology and Related Systemic Diseases Artificial Intelligence Screening Technology, Institute of Ophthalmic Diseases, Guangxi Academy of Medical Sciences, Nanning, China.
Guangxi Medical University, Nanning, China.
Front Med (Lausanne). 2025 Apr 25;12:1538359. doi: 10.3389/fmed.2025.1538359. eCollection 2025.
This study aimed to evaluate changes in visual quality among myopic patients with varying tear film stability after small incision lenticule extraction (SMILE) using the Optical Quality Analysis System (OQAS II).
This prospective study analyzed 141 patients who underwent SMILE surgery, selecting the right eye of each patient for analysis. Objective visual quality and tear film stability were assessed using the OQAS II preoperatively and at 1 week, 1 month, and 3 months postoperatively. Refractive error and uncorrected visual acuity were measured at the same time points. At the 1-week follow-up, all patients completed a visual quality questionnaire and underwent tear film break-up time (TBUT) measurement. These assessments were conducted to evaluate the correlation between subjective visual perception and objective visual quality, as well as to examine the relationship between the two methods of tear film evaluation.
No significant differences in UDVA or postoperative spherical and equivalent spherical values were observed between groups at any postoperative time point ( > 0.05). At 1 week and 1 month post-surgery, both groups exhibited elevated Objective Scatter Index (OSI) and Mean OSI values, while OV100%, OV20%, OV9%, MTF cutoff, and Strehl ratio (SR) decreased compared to preoperative levels (all < 0.05). By 3 months post-surgery, all objective visual quality parameters in the tear film stability group returned to preoperative levels ( > 0.05). In contrast, in the instability group, only SR remained unchanged, while other parameters significantly differed from baseline ( < 0.05). Positive correlations were found between OSI values and both foggy vision and glare at 1 week postoperatively in both groups. TF-OSI values positively correlated with blinking frequency and visual fluctuations. OV100% values at all preoperative and postoperative time points did not effectively predict subjective visual acuity.
Tear film instability negatively impacts visual quality recovery and prolongs corneal healing time after SMILE surgery. However, it does not cause short-term refractive regression. OV100% shows limited predictive ability for visual acuity. A significant correlation exists between objective visual quality and subjective perception. The OQAS II system is a valuable tool for assessing tear film stability and objective visual quality in refractive surgery patients.
本研究旨在使用光学质量分析系统(OQAS II)评估小切口透镜切除术(SMILE)后不同泪膜稳定性的近视患者的视觉质量变化。
这项前瞻性研究分析了141例行SMILE手术的患者,选取每位患者的右眼进行分析。术前及术后1周、1个月和3个月使用OQAS II评估客观视觉质量和泪膜稳定性。在相同时间点测量屈光不正和未矫正视力。在1周随访时,所有患者完成视觉质量问卷并进行泪膜破裂时间(TBUT)测量。进行这些评估以评估主观视觉感知与客观视觉质量之间的相关性,以及检查两种泪膜评估方法之间的关系。
在任何术后时间点,两组之间的最佳矫正视力(UDVA)或术后球镜和等效球镜值均未观察到显著差异(P>0.05)。术后1周和1个月,两组的客观散射指数(OSI)和平均OSI值均升高,而与术前水平相比,OV100%、OV20%、OV9%、调制传递函数截止频率(MTF cutoff)和斯特列尔比(SR)降低(均P<0.05)。术后3个月,泪膜稳定性组的所有客观视觉质量参数均恢复到术前水平(P>0.05)。相比之下,在不稳定组中只有SR保持不变,而其他参数与基线相比有显著差异(P<0.05)。两组术后1周时OSI值与模糊视觉和眩光均呈正相关。TF-OSI值与眨眼频率和视觉波动呈正相关。术前和术后所有时间点的OV100%值均不能有效预测主观视力。
泪膜不稳定对SMILE手术后的视觉质量恢复产生负面影响,并延长角膜愈合时间。然而,它不会导致短期屈光回退。OV100%对视力的预测能力有限。客观视觉质量与主观感知之间存在显著相关性。OQAS II系统是评估屈光手术患者泪膜稳定性和客观视觉质量的有价值工具。