动态导航在种植手术中的准确性:系统评价和荟萃分析。

Accuracy of dynamic navigation in implant surgery: A systematic review and meta-analysis.

机构信息

Department of Oral and Maxillo-facial Implantology, Shanghai Ninth People's Hospital, College of Stomatology, Shanghai Jiao Tong University School of Medicine, National Clinical Research Center for Oral Diseases, Shanghai Key Laboratory of Stomatology & Shanghai Research Institute of Stomatology, Shanghai, China.

出版信息

Clin Oral Implants Res. 2021 Apr;32(4):383-393. doi: 10.1111/clr.13719. Epub 2021 Feb 18.

Abstract

OBJECTIVE

To assess the accuracy of dynamic computer-assisted implant surgery.

MATERIALS AND METHODS

An electronic search up to March 2020 was conducted using PubMed, Embase, and the Cochrane Central Register of Controlled Trial to identify studies using dynamic navigation in implant surgery, and additional manual search was performed as well. Clinical trials and model studies were selected. The primary outcome was accuracy. A single-arm meta-analysis of continuous data was conducted. Meta-regression was utilized for comparison on study design, guidance method, jaw, and systems.

RESULTS

Ten studies, four randomized controlled trials (RCT) and six prospective studies, met the inclusion criteria. A total of 1,298 drillings and implants were evaluated. The meta-analysis of the accuracy (five clinical trials and five model studies) revealed average global platform deviation, global apex deviation, and angular deviation were 1.02 mm, 95% CI (0.83, 1.21), 1.33 mm, 95% CI (0.98, 1.67), and 3.59°, 95% CI (2.09, 5.09). Meta-regression shown no difference between model studies and clinical trials (p = .295, 0.336, 0.185), drilling holes and implant (p = .36, 0.279, 0.695), maxilla and mandible (p = .875, 0.632, 0.281), and five different systems (p = .762, 0.342, 0.336).

CONCLUSION

Accuracy of dynamic computer-aided implant surgery reaches a clinically acceptable range and has potential in clinical usage, but more patient-centered outcomes and socio-economic benefits should be reported.

摘要

目的

评估动态计算机辅助种植手术的准确性。

材料与方法

截至 2020 年 3 月,我们通过 PubMed、Embase 和 Cochrane 中央对照试验注册库进行了电子检索,以确定使用动态导航进行种植手术的研究,并进行了额外的手动检索。选择了临床试验和模型研究。主要结局为准确性。对连续数据进行了单项臂meta 分析。采用meta 回归比较了研究设计、指导方法、颌骨和系统。

结果

符合纳入标准的有 10 项研究,包括 4 项随机对照试验(RCT)和 6 项前瞻性研究。共评估了 1298 个钻头和种植体。准确性的meta 分析(5 项临床研究和 5 项模型研究)显示,平均全局平台偏差、全局根尖偏差和角度偏差分别为 1.02mm,95%置信区间(0.83,1.21)、1.33mm,95%置信区间(0.98,1.67)和 3.59°,95%置信区间(2.09,5.09)。Meta 回归显示,模型研究与临床试验之间、钻头和种植体之间、上颌骨和下颌骨之间以及 5 种不同系统之间均无差异(p=0.295、0.336、0.185、p=0.36、0.279、0.695、p=0.875、0.632、0.281、p=0.762、0.342、0.336)。

结论

动态计算机辅助种植手术的准确性达到了临床可接受的范围,具有临床应用的潜力,但应报告更多以患者为中心的结果和社会经济效益。