de Alves Melo Anna Fernanda Ferreira, de Castro Martinelli Roberta Lopes, de Andrade Rodrigo Alves, Lima Ana Paula Alves Figueiredo, de Almeida Aline Natallia Simões, Duque Anna Clara Mota, da Cunha Daniele Andrade, da Silva Hilton Justino
Federal University of Pernambuco, Av. Prof. Artur de Sá, s/n - Cidade Universitária, Recife, PE, CEP: 50674 - 420, Brazil.
Santa Therezinha Hospital, Av Rui Barbosa, 703 - Brotas, Brotas, CEP 17380 - 000, SP, Brazil.
BMC Pediatr. 2025 May 19;25(1):401. doi: 10.1186/s12887-025-05636-2.
This scoping review aimed to identify methodological procedures for acquiring and analyzing ultrasound images of the tongue during sucking in full-term infants. The Participants, Concept, and Context strategy was used to define the inclusion criteria: population (full-term infants); concept (ultrasound assessment); and context (assessment of tongue movements during sucking).
It included observational, experimental, descriptive, and analytical studies, and excluded those unavailable in full, with premature infants, babies with craniofacial changes and syndromes, studies on animals, in vitro, letters to the editor, errata, and using ultrasound for other purposes. There were no language or time restrictions. Two blinded professionals independently selected 20 articles that met the inclusion criteria from different databases.
The most evaluated parameters were related to the morphometric and kinematic aspects of the tongue, considering the physical behavior of the nipple and bottle nipple; sucking, swallowing, and breathing; distance from the tip of the nipple to the hard-soft palate junction; and milk flow. An endocavity transducer was positioned in the submental region at 5 MHz to 8 MHz. CONCLUSIONS: The studies present the acquisition and static analysis of ultrasound images of the tongue, hard and soft palate, nipple, and bottle nipple, and of kinematic measurements of the tongue, nipple, bottle nipple, and hyoid bone. They evaluated quantitative and qualitative parameters. Frequency adjustment depended on the child's age (the B mode was the most used), with babies reclined on the mother's lap to feed from the mother's breast and/or bottle.
本范围综述旨在确定获取和分析足月儿吸吮时舌头超声图像的方法步骤。采用参与者、概念和背景策略来定义纳入标准:人群(足月儿);概念(超声评估);背景(吸吮时舌头运动的评估)。
纳入观察性、实验性、描述性和分析性研究,排除那些全文不可获取的研究、早产儿研究、有颅面改变和综合征的婴儿研究、动物研究、体外研究、给编辑的信、勘误以及将超声用于其他目的的研究。没有语言或时间限制。两名盲法专业人员独立从不同数据库中筛选出20篇符合纳入标准的文章。
考虑到乳头和奶瓶奶嘴的物理行为、吸吮、吞咽和呼吸、乳头尖端到硬腭与软腭交界处的距离以及奶流情况,评估最多的参数与舌头的形态学和运动学方面有关。将腔内探头置于颏下区域,频率为5兆赫至8兆赫。
这些研究展示了舌头、硬腭和软腭、乳头和奶瓶奶嘴的超声图像的获取及静态分析,以及舌头、乳头、奶瓶奶嘴和舌骨的运动学测量。它们评估了定量和定性参数。频率调整取决于儿童年龄(B模式使用最为频繁),婴儿靠在母亲腿上从母亲乳房和/或奶瓶中进食。