Elaschuk Cole, Perverseff John, Getzlaf Matthew, Sauder David, Sims Laura
College of Medicine, University of Saskatchewan, Saskatoon, Canada.
Division of Orthopedic Surgery, Royal University Hospital, University of Saskatchewan, Saskatoon, Canada.
J Hand Surg Glob Online. 2025 Jun 3;7(4):100758. doi: 10.1016/j.jhsg.2025.100758. eCollection 2025 Jul.
Wrist range of motion (ROM) is an important assessment in wrist pathology. It is most commonly assessed using a long-arm goniometer. In-person intrarater reliability has been found to be high. Studies evaluating the assessment of wrist ROM virtually are less conclusive. The purpose of this study was to determine the validity and intrarater and inter-rater reliability of virtual wrist ROM measurements using a video coaching method.
We performed a prospective cohort study assessing wrist flexion, extension, pronation, and supination in healthy volunteers. Three assessors-medical student, research assistant, and upper-extremity surgeon-measured participant wrist ROM at in-person, same-day virtual, and repeat virtual time points, with a 1-week washout period. Measurements were made with a long-arm goniometer. Virtual assessments were performed over Zoom, allowing the assessor to coach volunteers on correct wrist positioning for accurate measurement, using a predefined protocol. Interclass correlation (ICC; 95% confidence intervals) was used to assess intra- and inter-rater reliability between each time point.
Fifty-three wrists were enrolled, with complete data available for 45 of them. For all raters and all ROM measures, ICC values for in-person measurements were >0.75, suggesting good inter-rater reliability. This was also seen for same-day and repeat virtual measures for all ROM measurements and raters (ICC >0.75), suggesting similar inter-rater reliability to in-person measurements. Intrarater reliability for in-person, same-day virtual, and repeat virtual was at least good (ICC > 0.75) for all raters and all ROM measurements. Supination had the highest intrarater reliability, with all raters having ICC values graded as excellent (ICC > 0.9).
Virtual wrist ROM assessments showed good inter-rater and intrarater reliability, with ICC scores comparable with in-person measures. This was true for raters of all levels of experience. Virtual wrist ROM assessment by this method offers a reliable alternative to in-person assessment.
Diagnostic IIb.
腕关节活动范围(ROM)是腕部病理学的一项重要评估指标。最常用长臂测角仪进行评估。已发现评估者内部的信度较高。评估虚拟腕关节ROM测量的研究结论性较差。本研究的目的是确定使用视频指导方法进行虚拟腕关节ROM测量的有效性以及评估者内部和评估者间的信度。
我们进行了一项前瞻性队列研究,评估健康志愿者的腕关节屈曲、伸展、旋前和旋后。三名评估者——医学生、研究助理和上肢外科医生——在现场、同日虚拟和重复虚拟时间点测量参与者的腕关节ROM,洗脱期为1周。使用长臂测角仪进行测量。通过Zoom进行虚拟评估,评估者可根据预定义方案指导志愿者正确摆放腕部位置以进行准确测量。组内相关系数(ICC;95%置信区间)用于评估各时间点之间评估者内部和评估者间的信度。
纳入了53个腕关节,其中45个有完整数据。对于所有评估者和所有ROM测量,现场测量的ICC值均>0.75,表明评估者间信度良好。对于所有ROM测量和评估者,同日和重复虚拟测量也呈现出这一结果(ICC>0.75),表明评估者间信度与现场测量相似。对于所有评估者和所有ROM测量,现场、同日虚拟和重复虚拟测量的评估者内部信度至少良好(ICC>0.75)。旋后的评估者内部信度最高,所有评估者的ICC值均为优秀(ICC>0.9)。
虚拟腕关节ROM评估显示出良好的评估者间和评估者内部信度,ICC分数与现场测量相当。所有经验水平的评估者均是如此。通过这种方法进行的虚拟腕关节ROM评估为现场评估提供了一种可靠的替代方法。
诊断性IIb级。