Suppr超能文献

传统扫描体与带有辅助几何装置的扫描体对比:一项关于无牙全牙弓种植体印模的研究

Conventional scan body vs. scan bodies with auxiliary geometric devices: an study for edentulous full-arch implant impressions.

作者信息

Gianfreda Francesco, Raffone Carlo, Martelli Mirko, Pitino Alberto, Caponio Vito Carlo Alberto, Bollero Patrizio

机构信息

Department of System Medicine, University of Rome "Tor Vergata", Rome, Italy.

Independent Researcher, Rome, Italy.

出版信息

Front Oral Health. 2025 Jun 2;6:1574149. doi: 10.3389/froh.2025.1574149. eCollection 2025.

Abstract

AIM

This study aimed to assess the effectiveness of an auxiliary geometric device (AGD) in enhancing the trueness of full-arch implant impressions. The primary metrics of interest were total surface deviation (TotRMS), centroid deviation (cRMS), and angular deviation. All these values are crucial for achieving a precise fit of implant-supported prostheses.

METHODS

A gypsum-based edentulous maxillary model with four multi-unit abutment replicas was prepared, replicating clinical scenarios. Control and experimental scan bodies were scanned using an intraoral scanner (Dexis 3800), and the resulting data were compared to a digital master model created with a structured light scanner (ATOS compact Scan 5M). The AGD was used to reduce positional errors during the scan process. Data were processed using Exocad and GOM Inspect Professional software, aligning scan body library files with mesh data using a best-fit algorithm. Angular, platform, and total deviations were calculated to assess positional trueness. A sample size of 20 scans per group was determined , and statistical comparisons were made using Mann-Whitney tests.

RESULTS

The inclusion of the AGD significantly reduced centroid root mean square (cRMS) values in all measured comparisons ( < 0.001), demonstrating enhanced trueness. The total body root mean square deviation TotRMS) values also showed a significant reduction ( = 0.002). While overall angular deviation differences were not statistically significant (meanAGD = 0.38; meanNO = 0.39; where "NO" refers to the group without AGD), site-specific analysis revealed significant improvements at points 2.4 ( = 0.017) and 1.4 ( < 0.001). The Euclidean distance in platform deviation consistently indicated better alignment in the AGD group.

CONCLUSION

The AGD, tested under conditions, significantly improved the trueness of full-arch implant impressions, particularly reducing c- and TotRMS values. These findings highlight the AGD's potential to enhance digital workflows in implant dentistry by mitigating positional discrepancies and ensuring greater trueness and precision. Future research should explore these findings in a clinical scenario.

摘要

目的

本研究旨在评估一种辅助几何装置(AGD)在提高全牙弓种植体印模准确性方面的有效性。主要关注的指标是总表面偏差(TotRMS)、质心偏差(cRMS)和角度偏差。所有这些值对于实现种植体支持的假体的精确贴合至关重要。

方法

制备一个带有四个多单位基台复制品的石膏基无牙上颌模型,模拟临床场景。使用口腔内扫描仪(Dexis 3800)对对照和实验扫描体进行扫描,并将所得数据与使用结构光扫描仪(ATOS compact Scan 5M)创建的数字主模型进行比较。AGD用于减少扫描过程中的位置误差。使用Exocad和GOM Inspect Professional软件处理数据,使用最佳拟合算法将扫描体库文件与网格数据对齐。计算角度、平台和总偏差以评估位置准确性。每组确定20次扫描的样本量,并使用曼-惠特尼检验进行统计比较。

结果

在所有测量比较中,AGD的纳入显著降低了质心均方根(cRMS)值(<0.001),表明准确性提高。总体体均方根偏差(TotRMS)值也显著降低(=0.002)。虽然总体角度偏差差异无统计学意义(平均AGD = 0.38;平均无AGD组 = 0.39;其中“无AGD组”指无AGD的组),但特定部位分析显示在点2.4(=0.017)和1.4(<0.001)处有显著改善。平台偏差中的欧几里得距离始终表明AGD组的对齐更好。

结论

在测试条件下,AGD显著提高了全牙弓种植体印模的准确性,特别是降低了cRMS和TotRMS值。这些发现突出了AGD通过减轻位置差异并确保更高的准确性和精度来增强种植牙科数字工作流程的潜力。未来的研究应在临床场景中探索这些发现。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/a480/12171148/4dbeb4d2af67/froh-06-1574149-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验