无离心机混合胶束介导的浊点萃取-分光光度法测定钒:使用4-硝基邻苯二酚和十六烷基氯化吡啶鎓

Centrifuge-Less Mixed Micelle-Mediated Cloud Point Extraction-Spectrophotometric Determination of Vanadium Using 4-Nitrocatechol and Cetylpyridinium Chloride.

作者信息

Gajdošová Andrea, Racheva Petya, Kiradzhiyska Denitsa, Divarova Vidka, Saravanska Antoaneta, Šandrejová Jana, Gavazov Kiril

机构信息

Department of Analytical Chemistry, Institute of Chemistry, Pavol Jozef Šafárik University in Košice, SK-04154 Košice, Slovakia.

Department of Chemical Sciences, Faculty of Pharmacy, Medical University of Plovdiv, 120 Buxton Bros Str., 4004 Plovdiv, Bulgaria.

出版信息

Int J Mol Sci. 2025 Jun 17;26(12):5808. doi: 10.3390/ijms26125808.

Abstract

A novel, environmentally friendly cloud point extraction (CPE) method based on 4-nitrocatechol (HL) was developed in this study to spectrophotometrically determine trace vanadium. This method utilizes a mixed micelle-mediated system comprising a cationic surfactant (cetylpyridinium chloride, CPC) and a nonionic surfactant (Triton X-114). In contrast to conventional CPE, the present approach does not employ centrifugation to separate the two phases. The distinguishing characteristic of the extracted species, (CP)[VOL], is its ability to absorb light across the entire visible spectrum. The measurement at 670 nm, where the complex displays a local maximum, is advantageous for two primary reasons. Firstly, the blank exhibits virtually no absorption, a property that engenders stable and reproducible results. Secondly, selectivity is high because almost all other metal complexes have absorption bands at shorter wavelengths. The proposed method has the following characteristics: a linear range of 2-305 ng mL, a limit of detection of 0.6 ng mL, a molar absorptivity coefficient of 1.22 × 10 M cm, a Sandell sensitivity of 0.42 ng cm, and a blue applicability grade index (BAGI) of 67.5. Its efficacy was demonstrated in the analysis of mineral water, a spent vanadium-containing catalyst, and a dietary supplement.

摘要

本研究开发了一种基于4-硝基邻苯二酚(HL)的新型环保浊点萃取(CPE)方法,用于分光光度法测定痕量钒。该方法利用了一种由阳离子表面活性剂(十六烷基氯化吡啶,CPC)和非离子表面活性剂(Triton X-114)组成的混合胶束介导体系。与传统的CPE不同,本方法不采用离心来分离两相。萃取物种(CP)[VOL]的显著特点是其在整个可见光谱范围内都有吸光能力。在670 nm处进行测量,该配合物在此处有一个局部最大值,这有两个主要优点。首先,空白几乎没有吸收,这一特性产生了稳定且可重复的结果。其次,选择性高,因为几乎所有其他金属配合物在较短波长处都有吸收带。所提出的方法具有以下特点:线性范围为2 - 305 ng/mL,检测限为0.6 ng/mL,摩尔吸光系数为1.22×10 M/cm,桑德尔灵敏度为0.42 ng/cm²,蓝色适用性等级指数(BAGI)为67.5。其有效性在矿泉水、废含钒催化剂和膳食补充剂的分析中得到了证明。