Abstract

Introductionin radiotherapy, fiducial markers improve the accuracy of radiation delivery, and their use has become increasingly important in the treatment of various cancers, particularly those in the prostate and lung. This work aims to determine, via Monte Carlo simulations and numerical ultrasound transport, the feasibility of fiducial marker localization via single-shot x-ray acoustic computed tomography.Methodspatient data from CT scans for two treatment sites, prostate and lung, were used to model the fiducial marker localization process. Monte Carlo simulation was used to calculate the absorbed dose distribution in each patient resulting from the irradiation with a 120 kVp x-ray imaging source, assuming that the dose is imparted in a short pulse. Ultrasound transport through each patient was modeled with the numerical ultrasound transport package k-Wave. For the image reconstruction process, as the exact internal patient structure will not be known at the time of treatment, a homogenous medium with the patient external contour and dimensions was used.ResultsIt is shown that the use of a homogeneous model to approximate the actual patient material composition during the reconstruction process, necessary as the geometry of the internal structures is not known at the time of the treatment, severely degrades the quality of the x-ray acoustic tomography images, but that it is still possible to determine the fiducial marker position with an accuracy of or better than 1 mm. The largest errors are observed for the lung patient when the lung is in an inflated state.Conclusionsit has been shown that single-shot x-ray acoustic tomography can be an effective tool for the tracking and localization of radiotherapy fiducial markers, exhibiting an accuracy of better than 1 mm, despite the poor visual quality of the resultant images.

摘要

引言

在放射治疗中,基准标记物可提高放射治疗的准确性,其应用在各种癌症的治疗中变得越来越重要,尤其是前列腺癌和肺癌的治疗。本研究旨在通过蒙特卡洛模拟和数值超声传输,确定通过单次X射线声计算机断层扫描进行基准标记物定位的可行性。

方法

使用来自前列腺和肺两个治疗部位的CT扫描患者数据来模拟基准标记物定位过程。蒙特卡洛模拟用于计算在120 kVp X射线成像源照射下每个患者的吸收剂量分布,假设剂量以短脉冲形式施加。使用数值超声传输软件包k-Wave对超声在每个患者体内的传输进行建模。对于图像重建过程,由于在治疗时患者体内的确切结构未知,因此使用具有患者外部轮廓和尺寸的均匀介质。

结果

结果表明,在重建过程中使用均匀模型来近似实际患者材料组成,这在治疗时由于内部结构的几何形状未知是必要的,但会严重降低X射线声断层扫描图像的质量,不过仍有可能以1毫米或更高的精度确定基准标记物的位置。当肺部处于膨胀状态时,肺部患者的误差最大。

结论

结果表明,单次X射线声断层扫描可以成为放射治疗基准标记物跟踪和定位的有效工具,尽管所得图像的视觉质量较差,但定位精度优于1毫米。