Laboratory evaluation of stain-length passive dosimeters for monitoring of vinyl chloride and ethylene oxide.

作者信息

Gonzalez L A, Sefton M V

出版信息

Am Ind Hyg Assoc J. 1985 Oct;46(10):591-8. doi: 10.1080/15298668591395382.

DOI:10.1080/15298668591395382
PMID:4061289
Abstract

The effects of vapor concentration in the range of 1.2 to 5.1 ppm (vinyl chloride) and 8.3 to 29.1 ppm (ethylene oxide) on the response of new stain-length passive dosimeters were evaluated separately in a dynamic exposure chamber. The vinyl chloride dosimeter was prepared with a permanganate impregnated blend of Chromosorb W and silica gel, while a silica gel-coated plastic strip (TLC plate) impregnated with dichromate was used to detect ethylene oxide. The use of a TLC plate as the inert support allowed us to reduce the amount of reagent loaded per length of tube, thus significantly enhancing in the sensitivity of the unit, which was necessary for accurately detecting ethylene oxide at these low concentrations. At the vinyl chloride exposure of 8 ppm-hrs the length of stain was 0.76 cm and the 95% confidence interval about this point was +/- 1.4 ppm-hrs (18%). For the ethylene oxide dosimeter the length of stain at the exposure of 80 ppm-hrs was 0.90 cm and the 95% confidence interval about this point was +/- 16 ppm-hrs (20%). Although some shortening of the stain was noted at low relative humidity (26%) in the vinyl chloride device, no effect on the dosimeter response was observed over the range of relative humidity of 35 to 96%. The ethylene oxide dosimeter response was not affected by relative humidity in the range of 28 to 90%. The use of a TLC plate as the inert support of the colorimetric reagent has proven to be an excellent means of improving the sensitivity of these stain-length passive dosimeters.(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

相似文献

1
Laboratory evaluation of stain-length passive dosimeters for monitoring of vinyl chloride and ethylene oxide.
Am Ind Hyg Assoc J. 1985 Oct;46(10):591-8. doi: 10.1080/15298668591395382.
2
Laboratory validation and field verification of a new passive air monitoring badge for sampling ethylene oxide in air.一种用于空气中环氧乙烷采样的新型被动式空气监测徽章的实验室验证和现场核查
Am Ind Hyg Assoc J. 1984 Oct;45(10):697-707.
3
Stain length passive dosimeter for monitoring of carbon monoxide.
Am Ind Hyg Assoc J. 1983 Jul;44(7):514-20. doi: 10.1080/15298668391405238.
4
Field validation of three passive dosimeters for excursion limit monitoring of ethylene oxide.用于环氧乙烷暴露极限监测的三种被动剂量计的现场验证
Am Ind Hyg Assoc J. 1991 Apr;52(4):151-6; discussion 156-7. doi: 10.1080/15298669191364505.
5
Laboratory validation of five commercially available methods for sampling ethylene oxide in air.
Am Ind Hyg Assoc J. 1985 Oct;46(10):620-4. doi: 10.1080/15298668591395418.
6
Development and validation of a protocol for field validation of passive dosimeters for ethylene oxide excursion limit monitoring.用于环氧乙烷暴露极限监测的被动剂量计现场验证方案的制定与验证
Am Ind Hyg Assoc J. 1991 Apr;52(4):145-50. doi: 10.1080/15298669191364497.
7
Extent of industrial exposure to epichlorohydrin, vinyl fluoride, vinyl bromide and ethylene dibromide.
Am Ind Hyg Assoc J. 1980 Jul;41(7):463-8. doi: 10.1080/15298668091425068.
8
A new method for monitoring personal exposure to ethylene oxide in the occupational environment.一种监测职业环境中个人环氧乙烷暴露情况的新方法。
Am Ind Hyg Assoc J. 1977 Nov;38(11):635-47. doi: 10.1080/00028897708984407.
9
The development and evaluation of a hydrobromic acid-coated sampling tube for measuring occupational exposures to ethylene oxide.用于测量职业性环氧乙烷暴露的氢溴酸涂层采样管的研制与评价
Am Ind Hyg Assoc J. 1987 Jun;48(6):563-73. doi: 10.1080/15298668791385228.
10
Measurement of atmospheric vinyl chloride.大气中氯乙烯的测量。
Am Ind Hyg Assoc J. 1979 Feb;40(2):96-107. doi: 10.1080/15298667991429390.