粘接间隙设置、聚合诱导的水泥收缩以及CAD/CAM牙冠的变形/适配的影响

Influence of luting space settings and polymerization-induced cement shrinkage and deformation/adaptation of CAD/CAM crowns.

作者信息

Pereira Leandro Maruki, Melo Bárbara Inácio de, Bicalho Aline Aredes, Pereira Rayssa Rodrigues, Prudente Marcel Santana, Soares Carlos José, Neves Flávio Domingues das

机构信息

Universidade Federal de Uberlândia - UFU, School of Dentistry, Department of Occlusion, Fixed Prosthodontics and Dental Materials, Uberlândia, MG, Brazil.

Universidade Federal de Uberlândia - UFU, Health Technical School (ESTES), Department of Basic, Technical and Technological Education, Uberlândia, MG, Brazil.

出版信息

Braz Oral Res. 2025 Jul 7;39:e074. doi: 10.1590/1807-3107bor-2025.vol39.074. eCollection 2025.

Abstract

This study aimed to evaluate the adaptation of CAD/CAM crowns and the impact of resin cement polymerization contraction on crown deformation under different cementation configurations. Thirty human molars were randomly divided into three groups (n = 10) to manufacture ceramic crowns with three different cementation space configurations: LD40 (40 μm), LD80 (80 μm), and LD160 (160 μm). The samples were subjected to computerized microtomography scanning for measuring internal and marginal adaptation, and internal fit was analyzed at occlusal, axial, axiogingival points. Five light-curing protocols were used to verify the wavelength spectrum peak of the curing device and the irradiance delivered using two situations: with 0 mm sensor distance and through a ceramic of differing thickness, and an external crown deformation (ECD) test. The highest statistically significant vertical fit was obtained for group LD40, independent of region. LD160 yielded the highest ECD values, independent of positioning of the buccal and distal strain gauge. The highest internal fit was observed at occlusal and axial points of the LD160 group (P<0.001), and LD80 yielded the lowest values at the axiogingival point (p = 0.003, p = 0.006). The irradiance delivered was reduced significantly upon interposition of the ceramic block to the sensor. The peak wavelength for curing was similar among the LD groups. The luting space configurations significantly influenced vertical fit and the ECD results for the CAD/CAM ceramics owing to polymerization shrinkage. Finally, variations in ceramic thickness at different sites affected both the irradiance by the curing device and ECD results.

摘要

本研究旨在评估CAD/CAM全冠的适应性以及在不同黏结配置下树脂水门汀聚合收缩对全冠变形的影响。将30颗人磨牙随机分为三组(n = 10),制作具有三种不同黏结间隙配置的陶瓷全冠:LD40(40μm)、LD80(80μm)和LD160(160μm)。对样本进行计算机断层扫描以测量内部和边缘适应性,并在咬合、轴向、轴龈点分析内部适合性。使用五种光固化方案来验证固化设备的波长光谱峰值以及在两种情况下传递的辐照度:传感器距离为0mm时以及通过不同厚度的陶瓷时,同时进行外部全冠变形(ECD)测试。LD40组在各区域均获得了统计学上最显著的垂直适合性。LD160组产生的ECD值最高,与颊侧和远中应变片的位置无关。在LD160组的咬合和轴位点观察到最高的内部适合性(P<0.001),而LD80组在轴龈点产生的数值最低(p = 0.003,p = 0.006)。当在传感器与光源之间插入陶瓷块时,传递的辐照度显著降低。LD各组之间的固化峰值波长相似。由于聚合收缩,黏结间隙配置对CAD/CAM陶瓷的垂直适合性和ECD结果有显著影响。最后,不同部位陶瓷厚度的变化对固化设备的辐照度和ECD结果均有影响。