Abstract

BACKGROUND

Stainless steel crowns (SSCs) are widely used in pediatric dentistry; however, their long-term biocompatibility remains a concern due to potential ion release. The oral environment's varying pH and temperature may influence the leaching of metal ions such as nickel, chromium, and titanium.

AIM

To estimate and compare the release of nickel, chromium, and titanium from three commercially available SSCs in artificial saliva at different pH levels (5.5, 6.5, and 7.5) over various time intervals (1, 3, and 6 months).

MATERIALS AND METHODS

Three different brands of SSCs were selected and grouped accordingly. Each group was further subdivided into three subgroups based on the pH of the artificial saliva (5.5, 6.5, and 7.5). The crowns were immersed in artificial saliva and incubated at 37°C. Samples were collected at 1, 3, and 6 months and analyzed using a spectrophotometer to measure the concentration of nickel, chromium, and titanium ions released, reported in parts per million (ppm). Statistical analysis was conducted to assess differences in ion release between groups and across time points.

RESULTS

There was a statistically significant variation in the release of metal ions across different pH levels and time intervals. Nickel and chromium were consistently detected in all groups, while titanium release was minimal. The ion release remained within biologically acceptable limits and was not considered toxic.

CONCLUSION

All tested SSCs released measurable amounts of nickel and chromium, with variations based on pH and duration.

摘要

背景

不锈钢冠(SSCs)在儿童牙科中广泛使用;然而,由于可能的离子释放,其长期生物相容性仍然是一个问题。口腔环境中不断变化的pH值和温度可能会影响镍、铬和钛等金属离子的浸出。

目的

评估并比较三种市售不锈钢冠在不同pH水平(5.5、6.5和7.5)的人工唾液中,在不同时间间隔(1、3和6个月)内镍、铬和钛的释放情况。

材料与方法

选择三种不同品牌的不锈钢冠并相应分组。根据人工唾液的pH值(5.5、6.5和7.5),每组再进一步细分为三个亚组。将牙冠浸入人工唾液中,在37°C下孵育。在1、3和6个月时收集样本,使用分光光度计进行分析,以测量释放的镍、铬和钛离子的浓度,以百万分之一(ppm)报告。进行统计分析以评估组间和不同时间点离子释放的差异。

结果

在不同pH水平和时间间隔下,金属离子的释放存在统计学上的显著差异。在所有组中均持续检测到镍和铬,而钛的释放量极少。离子释放量保持在生物学可接受的范围内,不被认为有毒。

结论

所有测试的不锈钢冠都释放出可测量的镍和铬,其释放量因pH值和持续时间而异。

相似文献

2
The effect of sample site and collection procedure on identification of SARS-CoV-2 infection.
Cochrane Database Syst Rev. 2024 Dec 16;12(12):CD014780. doi: 10.1002/14651858.CD014780.
3
Initial arch wires used in orthodontic treatment with fixed appliances.
Cochrane Database Syst Rev. 2024 Feb 6;2(2):CD007859. doi: 10.1002/14651858.CD007859.pub5.
4
Preformed crowns for decayed primary molar teeth.
Cochrane Database Syst Rev. 2015 Dec 31;2015(12):CD005512. doi: 10.1002/14651858.CD005512.pub3.
5
WITHDRAWN: Dental fillings for the treatment of caries in the primary dentition.
Cochrane Database Syst Rev. 2016 Oct 17;10(10):CD004483. doi: 10.1002/14651858.CD004483.pub3.
6
Dental fillings for the treatment of caries in the primary dentition.
Cochrane Database Syst Rev. 2009 Apr 15(2):CD004483. doi: 10.1002/14651858.CD004483.pub2.
7
Initial arch wires used in orthodontic treatment with fixed appliances.
Cochrane Database Syst Rev. 2018 Jul 31;7(7):CD007859. doi: 10.1002/14651858.CD007859.pub4.
8
Corrosion of copper nickel titanium archwire in chlorhexidine,  sodium fluoride, and chitosan mouthwashes.
F1000Res. 2024 May 30;12:159. doi: 10.12688/f1000research.129043.3. eCollection 2023.
10
Metal-free materials for fixed prosthodontic restorations.
Cochrane Database Syst Rev. 2017 Dec 20;12(12):CD009606. doi: 10.1002/14651858.CD009606.pub2.

本文引用的文献

1
An evaluation of biodegradability of stainless steel crowns at various salivary pH.
Indian J Dent Res. 2020 Jul-Aug;31(4):569-573. doi: 10.4103/ijdr.IJDR_761_18.
2
An evaluation of nickel and chromium release from different commercially available stainless steel crowns.
J Indian Soc Pedod Prev Dent. 2019 Jan-Mar;37(1):31-38. doi: 10.4103/JISPPD.JISPPD_176_17.
3
Nickel release from new conventional stainless steel, recycled, and nickel-free orthodontic brackets: An in vitro study.
Am J Orthod Dentofacial Orthop. 2010 Jun;137(6):809-15. doi: 10.1016/j.ajodo.2008.07.021.
4
Biodegradation of nickel and chromium from space maintainers: an in vitro study.
J Indian Soc Pedod Prev Dent. 2010 Jan-Mar;28(1):6-12. doi: 10.4103/0970-4388.60484.
6
Stainless steel crowns for deciduous molars.
J Am Dent Assoc. 1974 Aug;89(2):360-4. doi: 10.14219/jada.archive.1974.0409.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验