Suppr超能文献

将基于遥测的压力传感器手术植入颈内静脉以进行无线呼吸监测。

Surgical Implantation of a Telemetry-Based Pressure Sensor in the Internal Jugular Vein to Monitor Respiration Wirelessly.

作者信息

Kushwaha Neha, Dasgupta Debanjan

机构信息

Neural Circuit Dynamics Lab, Department of Biological Sciences and Bioengineering, Indian Institute of Technology, Kanpur, India.

出版信息

Bio Protoc. 2025 Jun 20;15(12):e5343. doi: 10.21769/BioProtoc.5343.

Abstract

Active sampling, such as respiration, is known to play a major role in modulating how sensory information is perceived and encoded in the field of olfaction. Hence, monitoring respiration is crucial for understanding olfactory-guided behavior and physiology. Several methods used to measure respiration, such as infrared cameras, piezoelectric sensors, video monitoring, temperature probes, intubation, and intranasal cannula, require the animal or at least its head to be fixed. However, telemetry-based sensors can be used wirelessly, allowing animals to move freely. Here, we describe the surgical protocol to implant a telemetry pressure sensor in the internal jugular vein to detect changes in thoracic pressure. The sensor can thus help in monitoring respiration by transmitting the signal wirelessly. We describe a way of inserting the probe into the right jugular vein aseptically while housing the transmitter underneath the skin on the back of the animal. Next, based on the optimal spot for the best signal, we secure the position of the probe and suture the skin. The animal then undergoes regular post-operative care with painkillers and soft diets for up to a week. The method offers two main advantages; first, it uses a strategy similar to the jugular vein catheterization, which is widely established in rodents. Second, it minimizes the need for extensive post-operative care, including not having to shift to a liquid diet post-recovery. This makes the animals fit for most behavioral experiments requiring water or food restrictions. Key features • Based on Dasgupta et al. [1], this protocol describes the surgical procedure involved in the aseptic implantation of the telemetry-based pressure sensor in the internal jugular vein. • Reduces the need for extensive post-operative care and eliminates dietary restrictions post-recovery. • The procedure helps in obtaining mice with an implanted sensor for wireless respiration recording.

摘要

主动采样,如呼吸,在嗅觉领域中对调节感觉信息的感知和编码起着重要作用。因此,监测呼吸对于理解嗅觉引导的行为和生理过程至关重要。几种用于测量呼吸的方法,如红外摄像机、压电传感器、视频监测、温度探头、插管和鼻内套管,都要求动物或至少其头部保持固定。然而,基于遥测的传感器可以无线使用,使动物能够自由活动。在这里,我们描述了一种手术方案,即在颈内静脉植入遥测压力传感器以检测胸内压力变化。该传感器因此可以通过无线传输信号来帮助监测呼吸。我们描述了一种在无菌条件下将探头插入右颈静脉的方法,同时将发射器置于动物背部皮肤下方。接下来,根据获得最佳信号的最佳位置,我们固定探头的位置并缝合皮肤。然后,动物接受为期一周的常规术后护理,包括使用止痛药和软食。该方法有两个主要优点;第一,它采用了一种类似于颈静脉插管的策略,这种策略在啮齿动物中已广泛应用。第二,它将术后广泛护理的需求降至最低,包括恢复后无需改为流食。这使得动物适合大多数需要限制水或食物的行为实验。关键特征 • 基于达斯古普塔等人的研究[1],本方案描述了在颈内静脉无菌植入基于遥测的压力传感器所涉及的手术过程。 • 减少了术后广泛护理的需求,并消除了恢复后的饮食限制。 • 该手术有助于获得植入传感器的小鼠以进行无线呼吸记录。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/26fb/12254592/705cb1891844/BioProtoc-15-12-5343-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验