Suppr超能文献

初步研究:使用Cytosorb®吸附器通过血液灌流对犬类血液中的血红蛋白进行体外还原。

Pilot study: In vitro reduction of hemoglobin from canine blood with hemoperfusion using the Cytosorb® adsorber.

作者信息

Spiegel Kathrin, Dörfelt René, Hartmann Katrin, Sänger Florian

机构信息

LMU Small Animal Clinic, Centre for Clinical Veterinary Medicine, Faculty of Veterinary Medicine, LMU München, Munich, Germany.

出版信息

PLoS One. 2025 Jul 28;20(7):e0328306. doi: 10.1371/journal.pone.0328306. eCollection 2025.

Abstract

Cell-free hemoglobin (cfHb) can be toxic and lead to kidney injury. This study assessed the in vitro reduction of cfHb from canine hemolyzed blood using hemoperfusion with a Cytosorb® cytokine adsorber. Canine whole blood was processed in linear and circular setups, with three runs each, at 100 mL/min. Hemolysis and osmolarity adjustments were performed with distilled water and hypertonic saline. Anticoagulation was optimized with heparin (10,000 IU/L). A median of 3.38 L of hemoglobin solution was processed in the linear setup. Samples were collected after the adsorber and from the waste bag. In the circular setup, a median of 2.09 L was processed, with samples taken before and after the adsorber. CfHb concentration was measured using the XT-2000iV® hematology analyzer (Sysmex). A control setup without an adsorber was run for 24 hours to assess cfHb stability. In the linear setup, cfHb concentration decreased by a median of 17.8% (14.7-26.8%), from 1.7 mmol/L to a minimum of 0.9 mmol/L, with 12.1 g (11.9-23.5 g) of cfHb removed. The median cfHb concentration after the adsorber displayed a logarithmic increase from 0.9 mmol/L (0.8-1.2 mmol/L) to 1.6 mmol/L (1.4-2.1 mmol/L). After processing 2.4 L, no further reduction occurred. In the circular setup, cfHb was reduced by a median of 41.3% (46.1-45.0%), representing 17.4 g (14.6-19.0 g) removed after 13.0 L (13.0-14.0 L). The reduction plateau was reached after 13 L. The hemoglobin reduction ratio in the circular setup at 3 L processed cfHb-solution was 25.0% (23.1-33.3%) and was not different from the linear setup (p = 0.400). The cfHb clearance decreased in both setups over time. CfHb concentration in the control setup was stable for 24 hours. Hemoperfusion with the Cytosorb® adsorber reduced cfHb in vitro from a canine blood solution.

摘要

游离血红蛋白(cfHb)可能具有毒性并导致肾损伤。本研究评估了使用Cytosorb®细胞因子吸附器进行血液灌流对犬溶血血液中cfHb的体外清除效果。犬全血在线性和循环装置中进行处理,每种装置各运行三次,流速为100 mL/分钟。使用蒸馏水和高渗盐水进行溶血和渗透压调整。用肝素(10,000 IU/L)优化抗凝。在线性装置中,中位数为3.38 L的血红蛋白溶液得到处理。在吸附器后和废物袋中采集样本。在循环装置中,中位数为2.09 L的血液得到处理,在吸附器前后采集样本。使用XT-2000iV®血液分析仪(Sysmex)测量cfHb浓度。运行一个无吸附器的对照装置24小时以评估cfHb的稳定性。在线性装置中,cfHb浓度中位数下降了17.8%(14.7 - 26.8%),从1.7 mmol/L降至最低0.9 mmol/L,清除了12.1 g(11.9 - 23.5 g)的cfHb。吸附器后cfHb浓度中位数从0.9 mmol/L(0.8 - 1.2 mmol/L)呈对数增加至1.6 mmol/L(1.4 - 2.1 mmol/L)。处理2.4 L后,cfHb浓度不再进一步降低。在循环装置中,cfHb中位数降低了41.3%(46.1 - 45.0%),相当于在处理13.0 L(13.0 - 14.0 L)血液后清除了17.4 g(14.6 - 19.0 g)的cfHb。处理13 L后达到降低平台期。在处理3 L cfHb溶液时,循环装置中的血红蛋白降低率为25.0%(23.1 - 33.3%),与线性装置无差异(p = 0.400)。两种装置中cfHb清除率均随时间下降。对照装置中的cfHb浓度在24小时内保持稳定。使用Cytosorb®吸附器进行血液灌流可在体外降低犬血液溶液中的cfHb。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/e020/12303300/b4f9b613c477/pone.0328306.g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验