具有相互连通孔隙结构的桡骨头假体,其柄周围显示出低骨吸收。

Radial Head Prosthesis with Interconnected Porosity Showing Low Bone Resorption Around the Stem.

作者信息

Vismara Valeria, Guerra Enrico, Accetta Riccardo, Cardile Carlo, Boero Emanuele, Aliprandi Alberto, Porta Marco, Zaolino Carlo, Marinelli Alessandro, Cazzaniga Carlo, Arrigoni Paolo

机构信息

Scuola di Specializzazione in Ortopedia e Traumatologia, Università Degli Studi Di Milano, 20122 Milan, Italy.

Shoulder and Elbow Unit, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy.

出版信息

J Clin Med. 2025 Aug 1;14(15):5439. doi: 10.3390/jcm14155439.

Abstract

: Radial head arthroplasty is a commonly preferred treatment for complex, unreconstructable radial head fractures. Recent studies have raised the question of whether factors such as bone resorption may be related to failure. This observational, retrospective, multicenter, spontaneous, and non-profit study aims to assess radiological outcomes, focusing on bone resorption around the stem, for radial head replacement using a modular, cementless radial head prosthesis with interconnected porosity. : A series of 42 cases was available for review. Patients underwent radial head arthroplasty using a three-dimensional-printed radial head prosthesis. Patients were eligible for inclusion if they had undergone at least one follow-up between 6 and 15 months post-operatively. A scoring system to detect bone resorption was developed and administered by two independent evaluators. : Forty-two patients (14 males, 28 females), with an average age of 59 ± 11 years (range: 39-80 years), were analyzed with a minimum of six months' and a maximum of 32 months' follow-up. At follow-up, 50 radiological evaluations were collected, with 29 showing ≤3 mm and 12 showing 3-6 mm resorption around the stem. The average resorption was 3.5 mm ± 2.3. No correlation was found between the extent of resorption and the time of follow-up. The developed scoring system allowed for a high level of correlation between the evaluators' measurements of bone resorption. : Radial head prosthesis with interconnected porosity provided a low stem resorption rate for patients after a radial head fracture at short-to-mid-term follow-up after the definition of a reliable and easy-to-use radiological-based classification approach. (Level of Evidence: Level IV).

摘要

桡骨头置换术是治疗复杂、无法重建的桡骨头骨折时常用的首选治疗方法。最近的研究提出了诸如骨吸收等因素是否可能与治疗失败有关的问题。这项观察性、回顾性、多中心、自发性和非营利性研究旨在评估使用具有相互连通孔隙的模块化、非骨水泥型桡骨头假体进行桡骨头置换后的放射学结果,重点关注假体柄周围的骨吸收情况。

共有42例病例可供回顾。患者接受了三维打印桡骨头假体的桡骨头置换术。如果患者在术后6至15个月之间至少接受了一次随访,则符合纳入标准。由两名独立评估人员开发并实施了一种检测骨吸收的评分系统。

对42例患者(14例男性,28例女性)进行了分析,平均年龄为59±11岁(范围:39 - 80岁),随访时间最短为6个月,最长为32个月。随访时,收集了50份放射学评估报告,其中29份显示假体柄周围骨吸收≤3 mm,12份显示骨吸收为3 - 6 mm。平均骨吸收为3.5 mm±2.3。未发现骨吸收程度与随访时间之间存在相关性。所开发的评分系统使评估人员对骨吸收的测量结果之间具有高度相关性。

在定义了一种可靠且易于使用的基于放射学的分类方法后,具有相互连通孔隙的桡骨头假体在桡骨头骨折患者的短期至中期随访中显示出较低的假体柄骨吸收率。(证据级别:IV级)