BACKGROUND

There are limited comparisons of graft configurations and fixation methods for the all-inside anterior cruciate ligament (ACL) technique based on a laboratory investigation.

PURPOSE/HYPOTHESIS: This review aimed to evaluate the biomechanical data from controlled laboratory studies on different graft configurations and fixation methods in correlation to graft strength and stability in all-inside ACL reconstruction. It was hypothesized that graft configuration and supplementary fixation would significantly contribute to graft strength and stability.

STUDY DESIGN

Scoping review.

METHODS

A literature search was conducted via PubMed on January 15, 2025, including studies that examined all-inside ACL graft techniques in a controlled biomechanical manner; reported data on stiffness and/or ultimate load to failure, and utilized cadaveric, porcine, or bovine tendons with cyclic loading and pull-to-failure testing protocols. A total of 150 studies were shortlisted before being narrowed down to 11 biomechanical studies, with descriptive statistical analysis performed.

RESULTS

This review demonstrated that quadrupled ACL grafts outperformed tripled grafts in stiffness and load to failure. Adjustable-loop devices provided robust primary fixation, while supplementary fixation further enhanced graft stability. Overall, 3 failure modes emerged: graft failure, fixation failure, and suture failure, directly linked to surgical technique choices. Findings established evidence-based benchmarks for optimizing all-inside ACL reconstruction outcomes.

CONCLUSION

Our search and review demonstrated that a quadruple-folded graft with the side-to-side suturing technique, suspended by 2 adjustable-loop devices with additional tensioning and knot tying, and supplementary fixation with tibial reinforcement appears to offer the most stability. This has the potential to optimize functional recovery after ACL reconstruction via improved graft stability and reduced rerupture rates.

摘要

背景

基于实验室研究,全内置前交叉韧带(ACL)技术的移植物构型和固定方法的比较有限。

目的/假设:本综述旨在评估来自对照实验室研究的生物力学数据,这些研究涉及不同的移植物构型和固定方法与全内置ACL重建中移植物强度和稳定性的相关性。假设移植物构型和辅助固定将显著有助于移植物强度和稳定性。

研究设计

范围综述。

方法

于2025年1月15日通过PubMed进行文献检索,包括以对照生物力学方式研究全内置ACL移植物技术的研究;报告关于刚度和/或极限破坏载荷的数据,并利用尸体、猪或牛肌腱进行循环加载和拉断试验方案。总共筛选出150项研究,然后缩小到11项生物力学研究,并进行描述性统计分析。

结果

本综述表明,四倍ACL移植物在刚度和破坏载荷方面优于三倍移植物。可调环装置提供了强大的初始固定,而辅助固定进一步增强了移植物稳定性。总体而言,出现了3种失效模式:移植物失效、固定失效和缝线失效,这与手术技术选择直接相关。研究结果为优化全内置ACL重建结果建立了循证基准。

结论

我们的检索和综述表明,采用并排缝合技术的四倍折叠移植物,由2个可调环装置悬吊,并进行额外的张紧和打结,以及用胫骨加强进行辅助固定,似乎提供了最大的稳定性。这有可能通过提高移植物稳定性和降低再破裂率来优化ACL重建后的功能恢复。