Abstract

While anatomic total shoulder arthroplasty is a successful procedure that provides reliable pain relief and restoration of function in most patients, its success has been limited by glenoid component loosening. While series reporting the outcomes of inlay glenoid components have demonstrated excellent clinical outcomes with low rates of component loosening and need for revision, surgeons have been hesitant to adopt these implants due to concerns of inadequate pain relief secondary to the remaining glenoid rim contacting the humeral head implant. The inset glenoid component, a variant of the traditional inlay components, has gained interest because its design aims to achieve similar stability to traditional inlay components through implantation within strong subchondral bone, reduce the amount of glenoid vault removed compared to inlay components, and has a glenoid face designed to limit the rocking-horse phenomenon. In limited series, the inset glenoid component has demonstrated superior biomechanical and clinical performance compared to traditional onlay glenoid components. Although there have been minimal clinical studies investigating the inset glenoid in comparison to onlay and inlay components to date, a subset of case series with short-term follow-up have demonstrated favorable outcomes. The purpose of this article was to review the design rationale, biomechanical evidence, and clinical performance of the inset glenoid component.

摘要

虽然解剖型全肩关节置换术是一种成功的手术,能为大多数患者提供可靠的疼痛缓解和功能恢复,但其成功受到肩胛盂假体松动的限制。虽然报道嵌体式肩胛盂假体结果的系列研究显示出优异的临床结果,假体松动率低且翻修需求少,但由于担心剩余肩胛盂边缘接触肱骨头假体导致疼痛缓解不足,外科医生一直对采用这些植入物持犹豫态度。内嵌式肩胛盂假体是传统嵌体式假体的一种变体,因其设计旨在通过植入坚固的软骨下骨实现与传统嵌体式假体相似的稳定性,与嵌体式假体相比减少肩胛盂穹窿切除量,且其肩胛盂表面设计可限制摇马现象,从而受到关注。在有限的系列研究中,与传统覆盖式肩胛盂假体相比,内嵌式肩胛盂假体已显示出卓越的生物力学和临床性能。尽管迄今为止,与覆盖式和嵌体式假体相比,对内嵌式肩胛盂的临床研究极少,但一部分短期随访的病例系列已显示出良好的结果。本文的目的是综述内嵌式肩胛盂假体的设计原理、生物力学证据和临床性能。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/a2d9/12386770/555880f64669/jcm-14-05820-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验