辅助几何装置对全口种植义齿印模测量准确性和扫描时间影响的评估

evaluation of the effect of auxiliary geometric device on measurement trueness and scanning time in full-arch implant impressions.

作者信息

Ateşalp İleri Sema, Büyükerkmen Emine Begüm

机构信息

Department of Prosthodontics, Faculty of Dentistry, Necmettin Erbakan University, Konya, Turkey.

出版信息

J Adv Prosthodont. 2025 Aug;17(4):197-209. doi: 10.4047/jap.2025.17.4.197. Epub 2025 Aug 19.

Abstract

PURPOSE

This study aimed to evaluate the effect of clinically practical auxiliary geometric devices (AGD) on measurement trueness and scan time in full-arch implant-supported prostheses, focusing on different intraoral scanners (IOS) and implant angulations.

MATERIALS AND METHODS

Four implants were planned in an edentulous maxillary arch and divided into two groups based on posterior implant angulation: Model A (Parallel) and Model B (30°). Each model was evaluated under three auxiliary geometric devices (AGD) application types (std, agd1, agd2), and scanned using three different intraoral scanners (IOSs) [3Shape Trios 3 (T), Medit i700 (M), and Cerec Primescan (PS)], resulting in nine groups per model (n = 10). Scanning times and faulty scans were recorded. A conventional impression (CON) was taken as a control and digitized with a desktop scanner. Trueness was analyzed using Geomagic Control X, with statistical significance set at < .05.

RESULTS

Group B had higher RMS values than Group A (40.3 µm vs. 34.7 µm). T_std in Group A (51.4 µm) and T_std (53.1 µm) and Con (50.7 µm) in Group B exceeded the acceptable deviation limit. AGDs reduced deviations to acceptable levels in the Trios 3. The Primescan scanner had the shortest scanning times. AGD use, especially in T_agd2 and M_agd2, shortened scan times and eliminated erroneous scans.

CONCLUSION

The use of AGD has a significant impact on scanners' scanning trueness and time.

摘要

目的

本研究旨在评估临床实用的辅助几何装置(AGD)对全牙弓种植支持式修复体测量准确性和扫描时间的影响,重点关注不同的口内扫描仪(IOS)和种植体角度。

材料与方法

在上颌无牙颌弓中植入4颗种植体,并根据后部种植体角度分为两组:模型A(平行)和模型B(30°)。每个模型在三种辅助几何装置(AGD)应用类型(std、agd1、agd2)下进行评估,并使用三种不同的口内扫描仪(IOS)[3Shape Trios 3(T)、Medit i700(M)和Cerec Primescan(PS)]进行扫描,每个模型产生9组(n = 10)。记录扫描时间和错误扫描情况。采用传统印模(CON)作为对照,并用台式扫描仪进行数字化处理。使用Geomagic Control X分析准确性,设定统计学显著性为< 0.05。

结果

B组的RMS值高于A组(40.3 µm对34.7 µm))。A组的T_std(51.4 µm)以及B组的T_std(53.1 µm)和Con(50.7 µm)超过了可接受的偏差限度。AGD将Trios 3中的偏差降低到可接受水平。Primescan扫描仪的扫描时间最短。使用AGD,尤其是在T_agd2和M_agd2中,缩短了扫描时间并消除了错误扫描。

结论

AGD的使用对扫描仪的扫描准确性和时间有显著影响。