Suppr超能文献

外斜视患者水平斜视手术后眼扭转的评估:使用传统彩色眼底照相术和Spectralis光学相干断层扫描的对比分析

Assessment of Ocular Torsion in Exotropic Patients Following Horizontal Strabismus Surgery: A Comparative Analysis Using Conventional Color Fundus Photography and Spectralis Optical Coherence Tomography.

作者信息

Abri Aghdam Kaveh, Abtahi Zahra-Alsadat, Zand Amin, Soltan Sanjari Mostafa, Sadeghi Ali, Zare Hosseinabadi Vahid, Sonbolestan Seyed Ali

机构信息

Eye Research Center, Ophthalmology Department, Moheb Kowsar Hospital, The Five Senses Health Institute, School of Medicine, Iran University of Medical Sciences, Tehran, Iran.

Department of Ophthalmology, Shafa Hospital, Kerman University of Medical Sciences, Kerman, Iran.

出版信息

J Ophthalmol. 2025 Sep 7;2025:1477145. doi: 10.1155/joph/1477145. eCollection 2025.

Abstract

To objectively evaluate ocular cycloposition using conventional color fundus photography (CFP) and Spectralis optical coherence tomography (OCT) in exotropic patients undergoing horizontal strabismus surgery and to assess the agreement between these methods. Additionally, we aimed to determine whether surgery alters ocular torsion in pure exotropia. In this prospective, single-center study, 42 eyes from 21 patients with exotropia requiring bilateral lateral rectus muscle recession were evaluated. The disc-center fovea angle (DFA) was measured pre- and postoperatively using CFP (Topcon fundus camera) and Spectralis OCT with fovea-to-disc (FoDi) alignment software. The angle of exodeviation improved significantly postoperatively, from 35.10 ± 7.89 to 3.76 ± 3.73 prism diopters ( < 0.001). Both CFP- and OCT-derived DFA values remained stable in both eyes at 6 months ( > 0.05 for all comparisons). No significant differences were observed between CFP and OCT measurements at baseline or postoperatively ( > 0.05). Preoperative intraclass correlation coefficient (ICC) between methods was strong (right eye: 0.765; left eye: 0.750), decreasing postoperatively to moderate levels (right eye: 0.618; left eye: 0.661). Horizontal strabismus surgery does not significantly alter ocular torsion in pure exotropia. Spectralis OCT reliably quantifies cyclotorsion but may yield marginally lower DFA values compared to CFP, despite no statistical difference.

摘要

目的是使用传统彩色眼底照相术(CFP)和Spectralis光学相干断层扫描(OCT)客观评估接受水平斜视手术的外斜视患者的眼旋转位置,并评估这些方法之间的一致性。此外,我们旨在确定手术是否会改变单纯外斜视患者的眼扭转。在这项前瞻性单中心研究中,对21例需要双侧外直肌后徙的外斜视患者的42只眼进行了评估。使用CFP(拓普康眼底相机)和带有黄斑-视盘(FoDi)对齐软件的Spectralis OCT在术前和术后测量视盘中心黄斑角(DFA)。术后外斜视角度显著改善,从35.10±7.89棱镜度降至3.76±3.73棱镜度(<0.001)。术后6个月,双眼CFP和OCT得出的DFA值均保持稳定(所有比较均>0.05)。基线或术后CFP和OCT测量之间未观察到显著差异(>0.05)。术前两种方法之间的组内相关系数(ICC)很强(右眼:0.765;左眼:0.750),术后降至中等水平(右眼:0.618;左眼:0.661)。水平斜视手术不会显著改变单纯外斜视患者的眼扭转。Spectralis OCT能够可靠地量化眼旋转,但与CFP相比,DFA值可能略低,尽管无统计学差异。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/9baf/12433727/fcb83d4e7e6d/JOPH2025-1477145.001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验