Liu C T, KeLauter R D
Am J Vet Res. 1977 Nov;38(11):1843-8.
Techniques for measurements of selected pulmonary functions for a period of 6 hours in conscious and lightly anesthetized rhesus macaques are described. Among all variables measured, only higher PaCO2 (367 +/- 32 mm of Hg) occurred in macaques breathing O2 as compared with those breathing room air. Tidal volume, respiratory rate, minute volume, O2 consumption, and specific ventilation in conscious and anesthetized monkeys were not significantly different. Further, respiratory and metabolic values from lightly anesthetized macaques in the present study agree well with the reports of others. However, differences were the higher values for O2 consumption, tidal volume, respiratory rate, and minute volume obtained with the presently described techniques as compared with certain reported data.
本文描述了在清醒和轻度麻醉的恒河猴身上测量选定肺功能6小时的技术。在所有测量变量中,与呼吸室内空气的恒河猴相比,呼吸氧气的恒河猴仅出现较高的动脉血二氧化碳分压(367±32毫米汞柱)。清醒和麻醉猴子的潮气量、呼吸频率、分钟通气量、氧气消耗量和比通气量无显著差异。此外,本研究中轻度麻醉恒河猴的呼吸和代谢值与其他报告结果非常吻合。然而,与某些报告数据相比,使用本文所述技术获得的氧气消耗量、潮气量、呼吸频率和分钟通气量的值较高。