Abstract

This research has been carried out in order to estimate minimum sampling periods for the substances detailed in the VLP table given by the Italian Occupational Medicine Service and the Industrial Hygiene Group. These data take the following points into consideration: 1) sensitivity of the analytical method; 2) value and condition of sample at fulfilment of sampling periods; 3) sampling speed; 4) VLP, with special reference to ceiling value for very short exposure. As to dust the minimum period required is about 1 minute for numeric sampling, and 35 minutes for gravimetric sampling. 85% from the above-mentioned substances can be sampled at minimum periods which range from 1 to 5 minutes.

摘要

开展这项研究是为了估算意大利职业医学服务机构和工业卫生组织给出的VLP表中详细列出的物质的最短采样周期。这些数据考虑了以下几点:1)分析方法的灵敏度;2)采样周期结束时样品的值和状况;3)采样速度;4)VLP,特别提及极短暴露的上限值。对于粉尘,数字采样所需的最短时间约为1分钟,重量采样为35分钟。上述物质中85%可以在1至5分钟的最短周期内进行采样。