Suppr超能文献

正常和重症肌无力患者终板处的终板电流及乙酰胆碱噪声

End-plate currents and acetylcholine noise at normal and myasthenic human end-plates.

作者信息

Cull-Candy S G, Miledi R, Trautmann A

出版信息

J Physiol. 1979 Feb;287:247-65. doi: 10.1113/jphysiol.1979.sp012657.

Abstract
  1. The amplitudes and time courses of miniature end-plate currents (m.e.p.c.s) have been compared at normal and myasthenic (MG) human end-plates studied under voltage clamp. The m.e.p.c. amplitude at MG end-plates is reduced to about one third normal; mean m.e.p.c. (normal) = 2.6 +/- 0.2 nA, mean m.e.p.c. (MG) = 1.0 +/- 0.1 nA. The decay time constant of m.e.p.c.s (tau m.e.p.c.) is very similar at normal and MG end-plates; tau m.e.p.c. (normal) = 1.70 +/- 0.1 msec, tau m.e.p.c. (MG) = 1.80 +/- 0.13 msec (Vm = - 80 mV. T = 23 degrees C). 2. The equilibrium potential of the end-plate current (e.p.c.) at normal and myasthenic human end-plates is close to 0 mV. 3. Decay time constants tau e.p.c. and tau m.e.p.c. increase exponentially with membrane hyperpolarization. The voltage sensitivity of the time constants was similar at normal and MG end-plates. 4. Both normal and myasthenic e.p.c.s are greatly prolonged in the presence of neostigmine (10(-6) g/ml.). At the same time the voltage sensitivity of tau e.p.c. is slightly reduced. 5. In response to steady ionophoretically applied ACh the mean membrane currents obtained at MG end-plates were smaller than the normal under similar conditions. 6. Analysis of end-plate current noise obtained during the steady application of acetylcholine (ACh) to voltage clamped normal and MG human end-plates showed that the amplitude of the elementary current event (gamma) and the average channel life-fime (tau noise) was similar at the two sites: tau noise (normal) - 1.54 +/- 0.04 msec, tau noise (MG) = 1.60 +/- 0.11 msec; gamma(normal) - 22.3 +/- 1.57 PS, gamma (MG) = 20.25 +/- 1.93 pS (Vm = - 80 mV, T = 23 degrees C). The voltage sensitivity of the channel life time, measured from end-plate current noise, was similar at normal and MG end-plates. 7. At normal human end-plates a packet of transmitter opens about 1500 channels whereas at MG end-plates a packet opens only about 600 channels. It is calculated that the size of the transmitter packets released from MG-terminals is at least as large as the packet of the ACh released from normal human nerve terminals.
摘要
  1. 已在电压钳制下对正常和重症肌无力(MG)患者的运动终板处微小终板电流(m.e.p.c.s)的幅度和时间进程进行了比较。MG患者终板处的m.e.p.c.幅度降至正常的约三分之一;平均m.e.p.c.(正常)=2.6±0.2nA,平均m.e.p.c.(MG)=1.0±0.1nA。m.e.p.c.s的衰减时间常数(tau m.e.p.c.)在正常和MG终板处非常相似;tau m.e.p.c.(正常)=1.70±0.1毫秒,tau m.e.p.c.(MG)=1.80±0.13毫秒(Vm = -80mV,T = 23℃)。2. 正常和重症肌无力患者终板电流(e.p.c.)的平衡电位接近0mV。3. 衰减时间常数tau e.p.c.和tau m.e.p.c.随膜超极化呈指数增加。正常和MG终板处时间常数的电压敏感性相似。4. 在新斯的明(10⁻⁶g/ml)存在的情况下,正常和重症肌无力患者的e.p.c.s均显著延长。同时,tau e.p.c.的电压敏感性略有降低。5. 响应离子电渗法稳定施加的乙酰胆碱(ACh),在类似条件下,MG终板处获得的平均膜电流小于正常情况。6. 对稳定施加乙酰胆碱(ACh)于电压钳制的正常和MG患者运动终板期间获得的终板电流噪声分析表明,两个部位的基本电流事件幅度(gamma)和平均通道寿命(tau noise)相似:tau noise(正常) - 1.54±0.04毫秒,tau noise(MG)=1.60±0.11毫秒;gamma(正常) - 22.3±1.57皮秒,gamma(MG)=20.25±1.93皮秒(Vm = -80mV,T = 23℃)。从终板电流噪声测量的通道寿命的电压敏感性在正常和MG终板处相似。7. 在正常人体运动终板处,一包递质打开约1500个通道,而在MG终板处,一包递质仅打开约600个通道。据计算,从MG终末释放递质包的大小至少与从正常人体神经终末释放的ACh包一样大。

相似文献

引用本文的文献

本文引用的文献

3
Active phase of frog's end-plate potential.青蛙终板电位的活动期
J Neurophysiol. 1959 Jul;22(4):395-411. doi: 10.1152/jn.1959.22.4.395.
5
The membrane change produced by the neuromuscular transmitter.神经肌肉递质产生的膜变化。
J Physiol. 1954 Sep 28;125(3):546-65. doi: 10.1113/jphysiol.1954.sp005180.
9
A quantitative description of end-plate currents.终板电流的定量描述。
J Physiol. 1972 May;223(1):173-97. doi: 10.1113/jphysiol.1972.sp009840.