Abstract

Plasma exchange has been proposed as a treatment for multiple disorders. Three patients with amyotropic lateral sclerosis, who were hemostatically normal, were studied through a total of 11 4-liter exchanges. Plasma was replaced by an equal volume of 5% albumin or 5% plasma protein fraction. Serial studies revealed that immediately after the exchange transfusion, there was significant prolongation of the prothrombin, partial thromboplastin, and thrombin times with reduction of the fibrinogen and antithrombin III levels. Factors V, VII-X, IX, and X were all significantly decreased, as were the factor VIII antigen, procoagulant, and the ristocetin cofactor activities. Platelet counts were obtained before and after exchanges and revealed significant decreases. Four hours after exchange, all parameters remained abnormal except the factor IX, ristocetin cofactor, and factor VIII procoagulant activities. By 24 hr, all hemostatic parameters had returned to normal. These studies indicate that plasma-exchange transfusion with material devoid of coagulation factors results in a coagulation defect that may be of clinical significance in a hemostatically compromised patient.

摘要

血浆置换已被提议用于多种疾病的治疗。对三名止血功能正常的肌萎缩侧索硬化症患者进行了总共11次4升的置换研究。用等量的5%白蛋白或5%血浆蛋白组分替代血浆。系列研究显示,在换血后即刻,凝血酶原时间、部分凝血活酶时间和凝血酶时间显著延长,纤维蛋白原和抗凝血酶III水平降低。因子V、VII-X、IX和X均显著下降,因子VIII抗原、促凝活性和瑞斯托菌素辅因子活性也下降。在置换前后进行血小板计数,结果显示显著减少。置换后4小时,除因子IX、瑞斯托菌素辅因子和因子VIII促凝活性外,所有参数仍异常。到24小时时,所有止血参数均恢复正常。这些研究表明,用缺乏凝血因子的物质进行血浆置换输血会导致凝血缺陷,这在止血功能受损的患者中可能具有临床意义。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验