• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

10-0尼龙缝线的并发症

Complications of 10-0 nylon sutures.

作者信息

Stewart R H, Kimbrough R L

出版信息

Ophthalmic Surg. 1979 Jul;10(7):19-21.

PMID:481858
Abstract

Three cases are presented which document the finding that 10-0 monofilament nylon suture may cut through corneal tissue after a coup or contrecoup injury to a recently operated eye. The authors speculate that a larger gauge suture does not have the tendency to cut through recently operated corneal tissue as easily as 10-0 monifilament nylon. The authors recommend the use of a larger gauge suture in closing corneal incisions in persons whom the surgeon feels are at a greater postoperative traumatic risk.

摘要

本文报告了3例病例,这些病例证实了一个发现:对于近期接受手术的眼睛,在受到对冲伤或反冲伤后,10-0单丝尼龙缝线可能会切割角膜组织。作者推测,较粗规格的缝线不像10-0单丝尼龙那样容易切割近期手术过的角膜组织。作者建议,对于外科医生认为术后创伤风险较高的患者,在缝合角膜切口时使用较粗规格的缝线。

相似文献

1
Complications of 10-0 nylon sutures.10-0尼龙缝线的并发症
Ophthalmic Surg. 1979 Jul;10(7):19-21.
2
[Spontaneous rupture of nylon sutures in the cornea spontaneously (author's transl)].角膜中尼龙缝线的自发性断裂(作者译)
Klin Monbl Augenheilkd. 1977 Sep;171(3):392-5.
3
[Early keratoplasty after perforating injury of the cornea (author's transl)].角膜穿孔伤后的早期角膜移植术(作者译)
Klin Monbl Augenheilkd. 1975 Sep;167(3):427-34.
4
[Experiments on animals to investigate the suitability of perforating corneal sutures (author's transl)].
Klin Monbl Augenheilkd. 1975 Sep;167(3):434-6.
5
Complications associated with running 11-0 nylon suture in penetrating keratoplasty.穿透性角膜移植术中使用11-0尼龙缝线相关的并发症。
Ophthalmic Surg. 1982 Jul;13(7):558-61.
6
Comparison of complication rates and postoperative astigmatism between nylon and mersilene sutures for corneal transplants in patients with Fuchs endothelial dystrophy.富克斯内皮营养不良患者角膜移植中尼龙缝线与涤纶缝线的并发症发生率及术后散光比较。
Cornea. 2006 Jun;25(5):533-9. doi: 10.1097/01.ico.0000214218.60249.e5.
7
Suture use in pediatric cataract surgery: a survey.
Ophthalmic Surg. 1993 Aug;24(8):554-5.
8
The clinical evaluation of 9-0 and 10-0 monofilament Polyglactin 910 absorbable suture for corneal surgery.用于角膜手术的9-0和10-0单丝聚乙醇酸910可吸收缝线的临床评估。
Ophthalmic Surg. 1979 Jan;10(1):50-2.
9
Astigmatism after mersilene and nylon suture use for penetrating keratoplasty.用于穿透性角膜移植术的丝裂霉素和尼龙缝线术后散光
Cornea. 2006 Jul;25(6):691-4. doi: 10.1097/01.ico.0000208821.32614.49.
10
Complications of Mersilene sutures in penetrating keratoplasty.梅氏尼龙缝线在穿透性角膜移植术中的并发症
Refract Corneal Surg. 1992 Jul-Aug;8(4):296-305.