Aeration of medical plastics.

作者信息

Tock R M, Chen Y C

出版信息

J Biomed Mater Res. 1974 Jan;8(1):69-80. doi: 10.1002/jbm.820080109.

DOI:10.1002/jbm.820080109
PMID:4819875
Abstract

Because the metabolic reaction that gives ethylene oxide is sterilizing qualities also takes place with human protein, it is imperative that any residual gas be removed before the sterilized material is used on the patient. This paper presents a method of estimating aeration time required following sterilization of polyvinyl choride (PVC) to reduced toxic residues to a desired level. The method proposed involves calculation of the coefficient of diffusivity, and the use of a simplified diffusion equation to estimate aeration time.

摘要

相似文献

1
Aeration of medical plastics.
J Biomed Mater Res. 1974 Jan;8(1):69-80. doi: 10.1002/jbm.820080109.
2
Aeration time following ethylene oxide sterilization for reusable rigid sterilization containers: concentration of gaseous ethylene oxide in containers.可重复使用的刚性灭菌容器经环氧乙烷灭菌后的通气时间:容器内气态环氧乙烷的浓度
Biomed Instrum Technol. 2000 Mar-Apr;34(2):121-4.
3
Kinetics of the aeration of ethylene-oxide sterilized plastics.环氧乙烷灭菌塑料的通气动力学。
Biomaterials. 1980 Jul;1(3):149-57. doi: 10.1016/0142-9612(80)90038-1.
4
[Cytotoxicity of PVC tubes sterilized in ethylene oxide after gamma radiation exposure].[γ射线照射后经环氧乙烷灭菌的聚氯乙烯管的细胞毒性]
Rev Esc Enferm USP. 2013 Apr;47(2):494-9. doi: 10.1590/s0080-62342013000200031.
5
[Ethylene oxide residues and aeration time after use of modern heated aerators (author's transl)].[现代加热通风器使用后的环氧乙烷残留量及通风时间(作者译)]
Zentralbl Bakteriol Mikrobiol Hyg B. 1980 Jun;171(1):18-24.
6
Microwave desorption: a combined sterilizer/aerator for the accelerated elimination of ethylene oxide residues from sterilized supplies.
Med Instrum. 1988 Feb;22(1):39-44.
7
Enhancement of the kinetics of the aeration of ethylene oxide sterilized polymers using microwave radiation.利用微波辐射增强环氧乙烷灭菌聚合物的通气动力学
J Biomed Mater Res. 1989 Feb;23(2):143-56. doi: 10.1002/jbm.820230202.
8
Physico-chemical and toxicologo-hygienic aspects of using ethylene oxide for the sterilization of medical appliances. Part I. Sorption and diffusion of ethylene oxide in polymeric materials.使用环氧乙烷对医疗器械进行灭菌的物理化学及毒理学卫生学方面。第一部分。环氧乙烷在聚合材料中的吸附与扩散。
J Hyg Epidemiol Microbiol Immunol. 1984;28(2):119-28.
9
[The effect of sterilization by ethylene oxide on residual amounts of chlorohydrin and ethylene glycol in medical devices made of PVC, previously irradiated by cobalt 60].
J Pharm Belg. 1985 Jul-Aug;40(4):213-21.
10
Ethylene oxide sterilization of medical devices--with special reference to the sporicidal activity and residual concentration of ethylene oxide and its secondary products.医疗器械的环氧乙烷灭菌——特别涉及环氧乙烷及其副产物的杀孢子活性和残留浓度
Bull Tokyo Med Dent Univ. 1982 Jun;29(2):23-35.