Thyopac-3, a new commercial test kit for the in-vitro assessment of thyroid function, has been appraised in a group of 411 patients. The Thyopac-3 test was found to be simple and rapid to perform and accurate in diagnosis. Of 117 patients shown to be euthyroid by other criteria, 5% had Thyopac-3 values outside the normal range (derived from a group of 135 normal patients), and 10 of 79 thyrotoxic and 4 of 37 hypothyroid patients had values within the normal range.In a direct comparison in 190 patients with the resin uptake test the Thyopac-3 test emerged very favourably in regard to diagnostic accuracy and was technically easier and quicker to carry out. There was a non-linear negative correlation between results from the two procedures.

摘要

Thyopac-3是一种用于体外评估甲状腺功能的新型商用检测试剂盒,已在411名患者中进行了评估。结果发现,Thyopac-3检测操作简单、快速,诊断准确。在117名经其他标准判定为甲状腺功能正常的患者中,5%的患者Thyopac-3值超出正常范围(该范围源自135名正常患者),79名甲状腺功能亢进患者中有10名以及37名甲状腺功能减退患者中有4名的检测值在正常范围内。在190名患者中与树脂摄取试验进行直接比较时,Thyopac-3检测在诊断准确性方面表现出色,并且在技术上更简便、执行更快。两种检测方法的结果之间存在非线性负相关。

相似文献

引用本文的文献

1
Natural history of autoimmune thyroiditis.自身免疫性甲状腺炎的自然病史。
Br Med J (Clin Res Ed). 1981 Jan 24;282(6260):258-62. doi: 10.1136/bmj.282.6260.258.
2
Free thyroxine index.游离甲状腺素指数
Br Med J. 1970 May 30;2(5708):543. doi: 10.1136/bmj.2.5708.543-a.
8
Grades of hypothyroidism.甲状腺功能减退的分级。
Br Med J. 1973 Mar 17;1(5854):657-62. doi: 10.1136/bmj.1.5854.657.

本文引用的文献

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验