Airway closure during anesthesia: a comparison between resident-gas and argon-bolus techniques.

作者信息

Hedenstierna G, Santesson J

出版信息

J Appl Physiol Respir Environ Exerc Physiol. 1979 Oct;47(4):874-81. doi: 10.1152/jappl.1979.47.4.874.

Abstract

Airway closure was measured in awake and then anesthetized supine healthy subjects with the argon-bolus and the resident-gas (nitrogen) techniques simultaneously. The preinspiratory lung volume for the closing volume maneuver was varied from residual volume to closing capacity (CC). Comparative measurements were also performed in the upright and supine positions in awake subjects. Closing volume (CV) was consistently larger with the bolus technique in supine subjects both when awake and when anesthetized (difference between methods 0.1--0.2 l, P less than 0.01), whereas no difference between the methods was noted in upright subjects. The lower "nitrogen CV" in supine subjects may be due to a shorter vertical lung height with a smaller range of nitrogen concentrations, resulting in a less abrupt onset of phase IV (taken to indicate CV). CV was not significantly affected by the preinspiratory lung volume with either technique, and CC was unchanged when anesthesia was instituted. Functional residual capacity (FRC) was reduced with anesthesia (mean reduction: 0.6 l, P less than 0.01) and FRC-CC became negative in all subjects with either technique. This implies intermittent or continuous airway closure during anesthesia and the possibility of increased venous admixture.

摘要

相似文献

1
Airway closure during anesthesia: a comparison between resident-gas and argon-bolus techniques.
J Appl Physiol Respir Environ Exerc Physiol. 1979 Oct;47(4):874-81. doi: 10.1152/jappl.1979.47.4.874.
2
Airway closure in each lung of anesthetized human subjects.
J Appl Physiol Respir Environ Exerc Physiol. 1981 Jan;50(1):55-64. doi: 10.1152/jappl.1981.50.1.55.
3
Closing capacity in awake and anesthetized-paralyzed man.
J Appl Physiol Respir Environ Exerc Physiol. 1978 Feb;44(2):238-44. doi: 10.1152/jappl.1978.44.2.238.
4
Closing capacity measurement during general anesthesia.
Anesthesiology. 1976 Nov;45(5):477-82.
6
Airway closure during mechanical ventilation.
Anesthesiology. 1976 Feb;44(2):114-23. doi: 10.1097/00000542-197602000-00003.
7
The lung volume at which shunting occurs with inhalation anesthesia.吸入麻醉时发生分流的肺容积。
Anesthesiology. 1988 Dec;69(6):854-61. doi: 10.1097/00000542-198812000-00009.
8
Regional intrapulmonary gas distribution in awake and anesthetized-paralyzed prone man.
J Appl Physiol Respir Environ Exerc Physiol. 1978 Oct;45(4):528-35. doi: 10.1152/jappl.1978.45.4.528.
9
Airway closure and closing volume.气道闭合与闭合容积
J Appl Physiol Respir Environ Exerc Physiol. 1979 Jan;46(1):24-30. doi: 10.1152/jappl.1979.46.1.24.

引用本文的文献

2
Variations of regional lung function in acute respiratory failure and during anaesthesia.
Intensive Care Med. 1984;10(4):169-77. doi: 10.1007/BF00259433.
3
High-frequency jet ventilation during oleic-acid induced pulmonary oedema.
Intensive Care Med. 1989;15(2):105-10. doi: 10.1007/BF00295986.
4
Perioperative functional residual capacity.
Can J Anaesth. 1991 Apr;38(3):384-400. doi: 10.1007/BF03007630.