Airway closure in each lung of anesthetized human subjects.

作者信息

Hedenstierna G, Bindslev L, Santesson J, Norlander O P

出版信息

J Appl Physiol Respir Environ Exerc Physiol. 1981 Jan;50(1):55-64. doi: 10.1152/jappl.1981.50.1.55.

DOI:10.1152/jappl.1981.50.1.55
PMID:7204192
Abstract

Airway closure and functional residual capacity (FRC) were assessed for each lung separately in the anesthetized subject by means of a double-lumen tracheal catheter. Airway closure was studied by argon-bolus and nitrogen-washout techniques, and FRC was calculated from single-breath nitrogen washout. Recordings were done with subjects in the supine and lateral postures. In the supine position, closing capacity (CC) exceeded FRC in each lung. Airway closure occurred synchronously in the two lungs. Argon CC was 0.05-0.1 liter larger than nitrogen CC of either lung. Minor gas trapping occurred during the vital capacity (VC) maneuver, so that inspired VC exceeded expired VC by 3%. In the left lateral posture, CC remained unaltered in either lung, whereas FRC was markedly increased in the nondependent and reduced in the dependent lung. Airway closure occurred asynchronously in the two lungs, and its distribution was discontinuous between them. Onset of airway closure in the dependent lung caused an early (60% VC) upstroke on the overall tracer gas recording (sampling of mixed expirate at the mouth), whereas onset of airway closure in the nondependent lung caused an additional upstroke at 10% VC. Gas trapping was more marked in the dependent lung than in the supine position, but some gas was released (expired VC greater than inspired VC) n the nondependent lung.

摘要

相似文献

1
Airway closure in each lung of anesthetized human subjects.
J Appl Physiol Respir Environ Exerc Physiol. 1981 Jan;50(1):55-64. doi: 10.1152/jappl.1981.50.1.55.
2
Pressure-volume and airway closure relationships in each lung in anaesthetized man.
Clin Physiol. 1981 Oct;1(5):479-93. doi: 10.1111/j.1475-097x.1981.tb00915.x.
3
Airway closure during anaesthesia, and its prevention by positive end expiratory pressure.麻醉期间的气道闭合及其通过呼气末正压通气的预防。
Acta Anaesthesiol Scand. 1980 Jun;24(3):199-205. doi: 10.1111/j.1399-6576.1980.tb01534.x.
4
Airway closure during anesthesia: a comparison between resident-gas and argon-bolus techniques.
J Appl Physiol Respir Environ Exerc Physiol. 1979 Oct;47(4):874-81. doi: 10.1152/jappl.1979.47.4.874.
5
Single-breath oxygen tests for individual lungs in awake man.清醒男性个体肺的单次呼吸氧气测试。
J Appl Physiol. 1976 Mar;40(3):305-11. doi: 10.1152/jappl.1976.40.3.305.
6
Cranio-caudal distribution of inspired gas and perfusion in supine man.
Respir Physiol. 1981 Jul;45(1):43-53. doi: 10.1016/0034-5687(81)90048-7.
7
Postural effects on lung volumes and asynchronous ventilation in anesthetized horses.姿势对麻醉马匹肺容量和不同步通气的影响。
J Appl Physiol Respir Environ Exerc Physiol. 1980 Jan;48(1):97-103. doi: 10.1152/jappl.1980.48.1.97.
8
Airway closure and closing pressure during mechanical ventilation.机械通气期间的气道闭合与闭合压
Acta Anaesthesiol Scand. 1980 Aug;24(4):299-304. doi: 10.1111/j.1399-6576.1980.tb01552.x.
9
Influence of lung volume history on closing volume measurement during anaesthesia.肺容积历史对麻醉期间闭合气量测量的影响。
Acta Anaesthesiol Scand. 1978;22(4):467-70. doi: 10.1111/j.1399-6576.1978.tb01324.x.
10
Airway closure and distribution of inspired gas in the extremely obese, breathing spontaneously and during anaesthesia with intermittent positive pressure ventilation.极度肥胖患者在自主呼吸及间歇正压通气麻醉期间气道关闭及吸入气体分布情况
Acta Anaesthesiol Scand. 1976;20(4):334-42. doi: 10.1111/j.1399-6576.1976.tb05047.x.

引用本文的文献

1
Successful 1:1 proportion ventilation with a unique device for independent lung ventilation using a double-lumen tube without complications in the supine and lateral decubitus positions. A pilot study.使用双腔管的独特独立肺通气装置在仰卧位和侧卧位成功实现1:1比例通气,且无并发症。一项初步研究。
PLoS One. 2017 Sep 14;12(9):e0184537. doi: 10.1371/journal.pone.0184537. eCollection 2017.
2
Variations of regional lung function in acute respiratory failure and during anaesthesia.
Intensive Care Med. 1984;10(4):169-77. doi: 10.1007/BF00259433.