Volpe F, Zintel J, Spiegel D
J Pharm Sci. 1979 Oct;68(10):1264-7. doi: 10.1002/jps.2600681018.
A reliable and selective high-pressure liquid chromatographic (HPLC) procedure for the quantitative determination of nylidrin hydrochloride or isoxsuprine hydrochloride in pharmaceutical dosage forms is described. The specificity of the stability-indicating HPLC procedure is presented for nylidrin hydrochloride.
本文描述了一种可靠且具选择性的高效液相色谱(HPLC)方法,用于定量测定药物剂型中的盐酸尼立替林或盐酸异克舒令。本文还展示了该稳定性指示HPLC方法对盐酸尼立替林的专属性。