Lykkelund C, Damgaard-Pedersen F
Scand J Clin Lab Invest. 1979 Sep;39(5):479-83. doi: 10.3109/00365517909106134.
A rapid fluorometric procedure for in situ evaluation of neutral lipids on thin-layer chromatograms is described. The lipids are rendered fluorescent by treatment with perchloric acid, and the intensity of the emitted light is recorded by flying spot scanning. Detection limits (2.8 x SD) are 0.10, 0.11, and 0.17 nmol for triglycerides, cholesterol, and cholesterol esters, respectively. Range of linearity is 0--3.4 nmol for triglycerides, 0--2.0 nmol for cholesterol, and 0--4.0 nmol for cholesterol esters. When standard in triplicate and 2 samples of each unknown are applied to the chromatogram, standard error of the mean is 2.7% for triglycerides, 1.7% for cholesterol, and 1.0% for cholesterol esters. The sensitivity of the method allows simultaneous determination of the three lipid classes in 5 microliter lipid extract representing 0.238 microliter human plasma.
本文描述了一种用于在薄层色谱图上原位评估中性脂质的快速荧光测定方法。脂质经高氯酸处理后产生荧光,发射光的强度通过飞点扫描记录。甘油三酯、胆固醇和胆固醇酯的检测限(2.8×标准差)分别为0.10、0.11和0.17 nmol。甘油三酯的线性范围为0 - 3.4 nmol,胆固醇为0 - 2.0 nmol,胆固醇酯为0 - 4.0 nmol。当将一式三份的标准品和每个未知样品的2个样本应用于色谱图时,甘油三酯的平均标准误差为2.7%,胆固醇为1.7%,胆固醇酯为1.0%。该方法的灵敏度允许在代表0.238微升人血浆的5微升脂质提取物中同时测定这三类脂质。