Suppr超能文献

采用高分辨率气相色谱-电子轰击、化学电离质谱法分析尿毒症血清。

Profiling of uremic serum by high-resolution gas chromatography-electron-impact, chemical ionization mass spectrometry.

作者信息

Schoots A C, Mikkers F E, Cramers C A, Ringoir S

出版信息

J Chromatogr. 1979 Sep 11;164(1):1-8. doi: 10.1016/s0378-4347(00)81565-0.

Abstract

A fast and reliable procedure for gas chromatographic profiling of components in ultrafiltrated uremic serum has been developed, using glass capillary columns. Sample pretreatment consists of ultrafiltration, evaporation and silylation. Some twenty components are identified by electron-impact and chemical ionization mass spectrometry. A comparison is made between profiles of sera from a series of uremic patients, before and after hemodialysis, and from non-uremic sera. Significant differences are found between these profiles. A "dialysis ratio" is introduced as a parameter for the removal of retained components by hemodialysis treatment.

摘要

已开发出一种使用玻璃毛细管柱对超滤尿毒症血清中的成分进行气相色谱分析的快速可靠方法。样品预处理包括超滤、蒸发和硅烷化。通过电子轰击和化学电离质谱法鉴定了约二十种成分。对一系列尿毒症患者血液透析前后的血清以及非尿毒症血清的图谱进行了比较。发现这些图谱之间存在显著差异。引入“透析率”作为血液透析治疗去除潴留成分的参数。