Chakrabarti R, Bielawiec M, Evans J F, Fearnley G R
J Clin Pathol. 1968 Nov;21(6):698-701. doi: 10.1136/jcp.21.6.698.
The euglobulin lysis time, which is widely used to measure blood fibrinolytic activity, is shown to be sensitive to the temperature and pH at which the euglobulin fraction of plasma is prepared and also to the type of anticoagulant employed and buffer in which it is suspended. A standardized method for performing the test, which controls these variables and has been found to yield reproducible results, is described. Since, at present, data obtained with this test by different laboratories are, for the reasons given, rarely comparable, it is hoped that the method outlined may be considered suitable for general adoption.
优球蛋白溶解时间广泛用于测量血液纤溶活性,结果表明,它对制备血浆优球蛋白组分时的温度和pH敏感,也受所用抗凝剂类型及其悬浮缓冲液的影响。本文描述了一种标准化的测试方法,该方法控制了这些变量,并已被证明能产生可重复的结果。由于目前不同实验室用该测试获得的数据因上述原因很少具有可比性,希望所概述的方法可被认为适合普遍采用。