Suppr超能文献

全髋关节置换术(TEP)中丙烯酸骨/骨水泥界面的术中温度测量(作者译)

[Intraoperative temperature measurements at the acrylic bone/cement interface in total hip endoprosthetic (TEP) implantations (author's transl)].

作者信息

Seidel H, Eggert A, Pietsch H

出版信息

Arch Orthop Unfallchir. 1977 Dec 27;90(3):251-7. doi: 10.1007/BF00415478.

Abstract

Temperature measurements are reported effected by aid of thermocouples enclosed in tubules in TEP-implantations of the hip. Two techniques were employed: the first using as acrylic bone cement Palacos or Sulfix-6 without concomitant cooling, the second Palacos after precooling of the femur with crushed ice/water mixtures. The first method yielded, at the acrylic bone cement/bone interface, temperatures above the coagulation point of the protein (56 degrees C). The novel technique of implantation is described, i.e. the cooling of the bone with ice-water prior to the cement implantation. This technique provides a means of restricting the average temperature at the aforesaid interface to 45 degrees C.

摘要

据报道,在髋关节的经皮电刺激(TEP)植入手术中,借助包裹在小管中的热电偶进行温度测量。采用了两种技术:第一种是使用Palacos或Sulfix - 6丙烯酸骨水泥,不伴随冷却;第二种是在用碎冰/水混合物对股骨进行预冷后使用Palacos。第一种方法在丙烯酸骨水泥/骨界面产生的温度高于蛋白质的凝固点(56摄氏度)。描述了新的植入技术,即在植入骨水泥之前用冰水冷却骨头。该技术提供了一种将上述界面的平均温度限制在45摄氏度的方法。