Suppr超能文献

脂质体在淋巴闪烁显像和淋巴给药中的潜在用途评估。锝-99m标记物在淋巴结中无法代表完整的脂质体。

Assessment of the potential uses of liposomes for lymphoscintigraphy and lymphatic drug delivery. Failure of 99m-technetium marker to represent intact liposomes in lymph nodes.

作者信息

Patel H M, Boodle K M, Vaughan-Jones R

出版信息

Biochim Biophys Acta. 1984 Sep 7;801(1):76-86. doi: 10.1016/0304-4165(84)90214-9.

Abstract

The in vivo fate of subcutaneously injected neutral SUV liposomes in rats was examined using a membrane marker, 99mTc, and an aqueous marker, 125I-labelled poly(vinyl pyrrolidone). Liposomes with entrapped 125I-labelled poly(vinyl pyrrolidone) were labelled with 99mTc by the SnCl2 method. 99mTc-radioactivity was localized several-fold more in the primary and secondary regional lymph nodes than 125I-labelled poly(vinyl pyrrolidone)-radioactivity. Similarly, 99mTc-radioactivity appeared and was subsequently cleared from the circulation much more rapidly than 125I-labelled poly(vinyl pyrrolidone). The gel chromatography of the lymph node homogenate revealed that 60-70% of 125I-labelled poly(vinyl pyrrolidone)-radioactivity was in the liposome fractions, whereas only 3% of 99mTc-radioactivity was co-eluted with the liposomes. Thus, the two markers have different fates in the lymphatics, and the presence of all 99mTc-radioactivity does not represent the 60-70% of intact liposomes present in lymph nodes. Using the aqueous marker 125I-labelled poly(vinyl pyrrolidone), the lymph node localization of positive, negative and neutral small unilamellar vesicles was studied, and it was found that 125I-radioactivity was more localized from negative liposomes than from positive liposomes, which in turn was more localized than that from neutral liposomes. Thus, these findings differ from those reported earlier, where the authors used 99mTc as a liposomal marker. In vitro studies showed that liposomes of preparations containing 20 mol% cholesterol became 'leaky' to low-molecular-weight drugs, for example, methotrexate (Mr 454) to a much greater extent than with a large-molecular-weight substance, 125I-labelled poly(vinyl pyrrolidone) (Mr 30 000-40 000), when incubated with rat lymph at 37 degrees C. Using the two markers 99mTc and 125I-labelled poly(vinyl pyrrolidone) it was found that the localization of both radioactivities was reduced in lymph nodes draining lambda-carrageenan-treated footpads. In conclusion, it is suggested that liposomes can be used for the delivery of drugs to diseased lymph nodes, and it would be worthwhile examining the possibilities of using alternative methods of labelling liposomes with 99mTc rather than using the SnCl2 technique, or using other radionuclides as markers for gamma-scan imaging.

摘要

使用膜标记物99mTc和水性标记物125I标记的聚乙烯吡咯烷酮,研究了皮下注射中性SUV脂质体在大鼠体内的命运。包封有125I标记的聚乙烯吡咯烷酮的脂质体通过SnCl2法用99mTc标记。99mTc放射性在一级和二级区域淋巴结中的定位比125I标记的聚乙烯吡咯烷酮放射性高几倍。同样,99mTc放射性比125I标记的聚乙烯吡咯烷酮更快地出现在循环中并随后从循环中清除。淋巴结匀浆的凝胶色谱显示,60 - 70%的125I标记的聚乙烯吡咯烷酮放射性在脂质体部分,而只有3%的99mTc放射性与脂质体共洗脱。因此,这两种标记物在淋巴管中的命运不同,所有99mTc放射性的存在并不代表淋巴结中存在的60 - 70%完整脂质体。使用水性标记物125I标记的聚乙烯吡咯烷酮,研究了阳性、阴性和中性小单层囊泡在淋巴结中的定位,发现125I放射性在阴性脂质体中的定位比在阳性脂质体中更多,而阳性脂质体又比中性脂质体中的定位更多。因此,这些发现与早期报道的不同,早期作者使用99mTc作为脂质体标记物。体外研究表明,含有20 mol%胆固醇的制剂的脂质体对低分子量药物,例如甲氨蝶呤(Mr 454)的“渗漏”程度比与大分子物质125I标记的聚乙烯吡咯烷酮(Mr 30 000 - 40 000)在37℃与大鼠淋巴孵育时大得多。使用99mTc和125I标记的聚乙烯吡咯烷酮这两种标记物发现,在引流λ-角叉菜胶处理的足垫的淋巴结中,两种放射性的定位都降低了。总之,建议脂质体可用于将药物递送至患病淋巴结,并且值得研究使用99mTc标记脂质体的替代方法而不是使用SnCl2技术,或使用其他放射性核素作为γ扫描成像标记物的可能性。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验